Literature DB >> 29267521

Retention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis.

Cleidiel Aparecido Araujo Lemos1, Fellippo Ramos Verri1, Joel Ferreira Santiago2, Daniel Augusto de Faria Almeida3, Victor Eduardo de Souza Batista1, Pedro Yoshito Noritomi4, Duardo Piza Pellizzer1.   

Abstract

The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29267521     DOI: 10.1590/0103-6440201801492

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  1 in total

1.  Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis.

Authors:  Cleidiel Aparecido Araujo Lemos; Fellippo Ramos Verri; Joel Ferreira Santiago Junior; Victor Eduardo de Souza Batista; Daniel Takanori Kemmoku; Pedro Yoshito Noritomi; Eduardo Piza Pellizzer
Journal:  J Healthc Eng       Date:  2018-09-03       Impact factor: 2.682

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.