Abstract
This study explored an alternative approach using rheology to assess setting time. The following cements were tested: ProRoot® MTA (Dentsply, Tulsa, OK, USA), Biodentine® (Septodont, Saint Maur des Fosses, France), Fuji VII®, FujiVII® EP, and Fuji IX® (from GC Corporation, Tokyo, Japan), RealSeal SE™ Sealer (SybronEndo, Amersfoort, The Netherlands), AH 26® and AH Plus (both from Dentsply DeTrey, Konstanz, Germany). Freshly mixed cements were placed into a strain-controlled rheometer (1 rad·s-1 with an applied strain of 0.01%). From measurements of elastic modulus over time, the time taken to reach 90% of the plateau elastic modulus (designated as the setting time) was determined for each cement. In increasing order, the setting times were as follows: Fuji VII EP 3.3 min, Fuji VII 3.6 min, Fuji IX 3.7 min, ProRoot MTA 5.1 min, Biodentine 15.9 min, RealSeal 22.2 min, AH Plus 5933 min, and AH 26 5067 min. However, ProRoot MTA did not yield reliable results. The time to reach the 90% plateau elastic modulus correlates well with the setting time of glass ionomer cements and Biodentine. Using this approach gives much longer setting times for endodontic sealers than previously recognized.Entities:
Keywords: Biodentine; bioceramics; dental materials; elastic modulus; endodontics; epoxy resin cement; glass ionomer; glass ionomer cement; mineral trioxide aggregate; physical properties
Year: 2017 PMID: 29261125 PMCID: PMC5744386 DOI: 10.3390/ma10121451
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1Parallel plates in a rheometer. A chamber can be constructed to maintain humidity and prevent desiccation of samples.
Figure 2Elastic (G’) modulus of tested dental cements over time. Different color plots are the trend lines for different replicate samples of the same material.
Plateau elastic modulus (in MPa).
| n | Mean (min) | SD (min) | SE | Margin of Error 1 (min) | Upper Bound (min) | Lower Bound (min) | Max (min) | Min (min) | Range (min) | |
|---|---|---|---|---|---|---|---|---|---|---|
| Fuji IX GP Extra | 3 | 1.7 × 108 | 1.5 × 107 | 8.8 × 106 | 1.73 × 107 | 1.84 × 108 | 1.49 × 108 | 1.80 × 108 | 1.50 × 108 | 3.00 × 107 |
| Fuji VII | 3 | 1.5 × 108 | 1.7 × 107 | 1.0 × 107 | 1.96 × 107 | 1.70 × 108 | 1.30 × 108 | 1.70 × 108 | 1.40 × 108 | 3.00 × 107 |
| Fuji VII EP | 3 | 1.4 × 108 | 3.2 × 107 | 1.9 × 107 | 3.64 × 107 | 1.73 × 108 | 1.00 × 108 | 1.60 × 108 | 1.00 × 108 | 6.00 × 107 |
| Biodentine | 3 | 1.1 × 108 | 5.8 × 106 | 3.3 × 106 | 6.53 × 106 | 1.20 × 108 | 1.07 × 105 | 1.20 × 108 | 1.10 × 108 | 1.00 × 107 |
| ProRoot MTA | 3 | 6.4 × 107 | 5.6 × 107 | 3.2 × 107 | 6.33 × 107 | 1.27 × 108 | 7.20 × 108 | 1.20 × 108 | 8.10 × 108 | 1.12 × 108 |
| RealSeal SE | 3 | 9.6 × 107 | 5.0 × 107 | 2.9 × 107 | 5.65 × 107 | 1.53 × 108 | 3.99 × 107 | 1.30 × 108 | 3.90 × 107 | 9.10 × 107 |
| AH 26 | 3 | 4.3 × 107 | 7.5 × 107 | 4.3 × 107 | 8.48 × 107 | 1.28 × 108 | −4.13 × 107 | 1.30 × 108 | 1.80 × 105 | 1.30 × 108 |
| AH Plus | 3 | 7.5 × 107 | 6.4 × 107 | 3.7 × 107 | 7.19 × 107 | 1.47 × 108 | 2.72 × 106 | 1.40 × 108 | 1.30 × 107 | 1.27 × 108 |
1 Confidence coefficient is set at 1.96. SD: Standard deviation; SE: Standard error.
Time to reach 90% of the plateau elastic modulus (in minutes).
| n | Mean (min) | SD (min) | SE | Margin of Error 1 (min) | Upper Bound (min) | Lower Bound (min) | Max (min) | Min (min) | Range (min) | |
|---|---|---|---|---|---|---|---|---|---|---|
| Fuji IX GP Extra | 3 | 3.7 | 0.1 | 0.0 | 0.1 | 3.8 | 3.7 | 3.8 | 3.7 | 0.1 |
| Fuji VII | 3 | 3.6 | 0.2 | 0.1 | 0.2 | 3.8 | 3.4 | 3.8 | 3.5 | 0.3 |
| Fuji VII EP | 3 | 3.3 | 0.3 | 0.2 | 0.3 | 3.6 | 3.0 | 3.5 | 3.0 | 0.5 |
| Biodentine | 3 | 15.9 | 2.8 | 1.6 | 3.1 | 19.0 | 12.7 | 18.5 | 13.0 | 5.5 |
| ProRoot MTA | 3 | 5.1 | 2.8 | 1.6 | 3.2 | 8.3 | 1.9 | 7.6 | 2.0 | 5.6 |
| RealSeal SE | 3 | 22.2 | 3.6 | 2.1 | 4.1 | 26.3 | 18.2 | 24.4 | 18.1 | 6.3 |
| AH 26 | 3 | 5066.7 | 1674.3 | 966.7 | 1894.7 | 6961.3 | 3172.0 | 7000.0 | 4100.0 | 2900.0 |
| AH Plus | 3 | 5933.3 | 1686.2 | 973.5 | 1908.1 | 7841.5 | 4025.2 | 7100.0 | 4000.0 | 3100.0 |
1 Confidence coefficient is set at 1.96. SD: Standard deviation; SE: Standard error.
Comparison of marketed setting times against proposed setting times using the time to reach 90% of the plateau elastic modulus.
| Dental Materials | Clinical Usage | Average Time to 90% Plateau G’ (min) | Marketed Setting Time 1 (min) | Testing Method of Setting Time 1 |
|---|---|---|---|---|
| Fuji IX GP Extra | General restorative | 3.7 | 2.0 | ISO 9917-1 |
| Fuji VII | General restorative | 3.6 | 2.5 | ISO 9917-1 |
| Fuji VII EP | General restorative | 3.3 | 2.5 | ISO 9917-1 |
| Biodentine | Root repair | 15.9 | 12.0 | Not stated |
| ProRoot MTA | Root repair | 5.1 | 240 | Not stated |
| RealSeal SE | Endodontic sealer | 22.2 | 45.0 | ISO 6876 |
| AH 26 | Endodontic sealer | 5933 | 540 to 900 | ISO 6876 |
| AH Plus | Endodontic sealer | 5066 | Minimum 480 | ISO 6876 |
1 According to manufacturer’s product information.