Literature DB >> 29254318

Perioperative plasmatic presepsin levels in patients undergoing total hip or knee replacement: a preliminary study.

G Vicenti1, V Pesce1, D Bizzoca1, V Nappi1, F Palmiotto1, M Carrozzo1, B Moretti1.   

Abstract

Presepsin (sCD14-ST) is an emerging biomarker in the diagnosis of sepsis. In the field of orthopaedics, it could be useful in the diagnosis and management of periprosthetic joint infections (PJI). The aim of this study is to define the normal perioperative plasmatic levels of presepsin in patients undergoing primary cementless total hip replacement (THR) or primary cemented total knee replacement (TKR). For this purpose, 50 patients (19 male, 31 female, mean age= 64.04±8.88) were recruited. The patients were divided into two groups: Group A patients underwent cementless THR, whereas Group B patients underwent cemented TKR. On recruitment, anthropometric data, smocking status, osteoarthritis stage according to Kellgren and Lawrence, Harris Hip Score (HHS) for Group A patients and Knee Society Score (KSS) for Group B patients, drugs assumption and comorbidities were recorded. All the patients underwent serial blood tests, including complete blood count, presepsin (PS), C-reactive protein (CRP) and procalcitonin (PCT) 24 hours before arthroplasty (T0) and at 24 (T1), 48 (T2), 72 (T3) and 96 (T4) hours postoperatively. Body temperature (θ) was recorded every six hours in the time lapse T0-T4. Presepsin plasmatic concentration was comparable at baseline in both groups. After surgery, however, a significant increase of presepsin was observed in Group A, whereas in Group B no significant changes of presepsin were recorded. A comparable trend of this biomarker was found in the two groups, i.e. presepsin increased from T0 to T3, when it reached its maximum value, and its decrease started at T4. Finally, presepsin resulted more accurate than CRP in the evaluation of perioperative inflammatory response in patients undergoing THR or TKR. These data will be helpful in defining a reference interval for presepsin in patients with prosthetic joint implants, and a cut-off of this biomarker for the diagnosis of PJI.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29254318

Source DB:  PubMed          Journal:  J Biol Regul Homeost Agents        ISSN: 0393-974X            Impact factor:   1.711


  2 in total

1.  Use of the 95-degree angled blade plate with biological and mechanical augmentation to treat proximal femur non-unions: a case series.

Authors:  Giovanni Vicenti; Giuseppe Solarino; Davide Bizzoca; Filippo Simone; Giuseppe Maccagnano; Giacomo Zavattini; Guglielmo Ottaviani; Massimiliano Carrozzo; Claudio Buono; Domenico Zaccari; Biagio Moretti
Journal:  BMC Musculoskelet Disord       Date:  2022-02-28       Impact factor: 2.362

Review 2.  The autoclaving and re-implantation of an infected prosthesis as a spacer during resection knee arthroplasty: a systematic review.

Authors:  Antonio Spinarelli; Davide Bizzoca; Lorenzo Moretti; Giovanni Vicenti; Raffaele Garofalo; Biagio Moretti
Journal:  Musculoskelet Surg       Date:  2021-07-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.