Literature DB >> 29253631

Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement.

Randall J Hlubek1, Michael A Bohl1, Tyler S Cole1, Clinton D Morgan1, David S Xu1, Steve W Chang1, Jay D Turner1, U Kumar Kakarla2.   

Abstract

BACKGROUND CONTEXT: C2 pedicle and pars screws require accurate placement to avoid injury to nearby neurovascular structures. Freehand, fluoroscopically guided, and computed tomography (CT)-based navigation techniques have been described in the medical literature.
PURPOSE: The present study aims to compare the safety and accuracy of the freehand technique versus stereotactic navigation for the placement of C2 pedicle and pars screws. STUDY DESIGN/
SETTING: This study was a retrospective review of consecutive patients treated with posterior fixation constructs. PATIENT SAMPLE: A total of 220 consecutive patients were treated with posterior fixation constructs containing C2 pars or pedicle screws placed at our institution. OUTCOME MEASURES: Computed tomography imaging was used to assess the accuracy of screw placement. Intraoperative complications and incidence of stroke or mortality within 30 days of the operation were analyzed.
METHODS: A retrospective review was conducted of consecutive patients treated with posterior fixation constructs containing C2 pars or pedicle screws placed by spine surgeons between January 1, 2010, and August 31, 2016. Clinical and radiographic data were collected and analyzed. Screw accuracy was graded independently by two reviewers according to the following criteria: grade A (no breach), grades B-E (breach with transverse foramen obstruction of 1%-25%, 26%-50%, 51%-75%, or 76%-100%, respectively), and grade M (medial breach). Screws were divided into acceptable (grades A and B) and unacceptable (grades C-E and M).
RESULTS: A total of 426 C2 pars or pedicle screws (312 freehand, 114 navigated) were placed in 220 patients (160 freehand, 60 navigated). Complications were similar between the groups: three vertebral artery injuries (two [1%] freehand, one [2%] navigated; p>.99), five deaths (four [3%] freehand, one [2%] navigated; p>.99), and one (2%) stroke in the navigated group (p=.61). Computed tomography imaging was available for accuracy grading of 182 screws (131 freehand, 51 navigated). No breaches (grade A) occurred in 113 of the freehand screws (86%) and in 34 of the navigated screws (67%) (p=.006). More screws had acceptable placement in the freehand group (123 of 131, 94%) than in the navigated group (42 of 51, 82%) (p=.02).
CONCLUSIONS: In patients with postoperative CT imaging (43%), the freehand technique was found to be more accurate than CT-based navigation for C2 pedicle or pars screw placement. Complication rates did not differ between the two techniques in this study.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Accuracy; C2 pars; C2 pedicle; C2 screw safety; CT-based navigation; Cervical spine; Complications; Freehand; Navigation; Vertebral artery

Mesh:

Year:  2017        PMID: 29253631     DOI: 10.1016/j.spinee.2017.12.003

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  8 in total

1.  The medial window technique as a salvage method to insert C2 pedicle screw in the case of a high-riding vertebral artery or narrow pedicle: a technical note and case series.

Authors:  Dong-Ho Lee; Sehan Park; Jae Hwan Cho; Chang Ju Hwang; Hyung Rae Lee; Sang Yun Seok; Choon Sung Lee
Journal:  Eur Spine J       Date:  2022-03-06       Impact factor: 2.721

Review 2.  3D-printed navigation template in cervical spine fusion: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Ali Azimi; Ali Montazeri
Journal:  Eur Spine J       Date:  2020-09-16       Impact factor: 3.134

3.  A novel screw view model of 3D navigation for upper cervical pedicle screw placement: A case report.

Authors:  Jianwu Zhao; Lili Yang; Shuang Zheng; Yang Qu; Xiwen Zhang; Mingyang Kang; Rongpeng Dong; Xin Zhao; Tong Yu
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

4.  Accuracy evaluation of placements of three different alternative C2 screws using the freehand technique in patients with high riding vertebral artery.

Authors:  Jong-Hyeok Park; Jong Beom Lee; Ho Jin Lee; Il Sup Kim; Jae Taek Hong
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

5.  Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation.

Authors:  Jun Seok Lee; Dong Wuk Son; Su Hun Lee; Sung Soon Ki; Sang Weon Lee; Geun Sung Song
Journal:  J Korean Neurosurg Soc       Date:  2020-02-27

6.  Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Hossein Nayeb Aghaei; Shirzad Azhari; Sohrab Sadeghi; Ali Montazeri
Journal:  J Orthop Surg Res       Date:  2020-07-20       Impact factor: 2.359

7.  A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation.

Authors:  Ye Tian; Jianan Zhang; Tuanjiang Liu; Shi Tang; Hao Chen; Keyuan Ding; Dingjun Hao
Journal:  Med Sci Monit       Date:  2019-12-26

8.  Combined 3-dimensional printing model and 3-dimensional fluoroscopic navigation to assist C2 pedicle screw insertion: A case report.

Authors:  Hao-Tian Xu; Shuang Zheng; Rong-Peng Dong; Tong Yu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2020-10-23       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.