Literature DB >> 29251451

CAD/CAM post-and-core using different esthetic materials: Fracture resistance and bond strengths.

Denis Roberto Falcão Spina1, Rogério Goulart da Costa1, Isabelli Carolini Farias2, Leonardo Gonçalves da Cunha2, André Vicente Ritter3, Carla Castiglia Gonzaga2, Giselle Maria Correr2.   

Abstract

PURPOSE: To evaluate the fracture resistance (FR), and push-out bond strengths (BS) of custom-made CAD/CAM post-and-cores manufactured with different esthetic materials.
METHODS: 90 single-rooted extracted teeth were selected, endodontically treated and prepared to receive the posts. The specimens were randomly divided into three equal groups according to the material: hybrid ceramic Vita Enamic (HC); nano-ceramic resin composite Lava Ultimate (RC); and experimental epoxy-resin reinforced by glass-fiber (FG). The post-and-cores were manufactured using CAD/CAM and cemented using a self-adhesive resin cement (Rely X Unicem2). A subgroup of 30 specimens (n=10) was subjected to fatigue (1,000,000 cycles at 5 Hz) and then to the FR test. Another subgroup with 60 specimens was submitted to the BS test, with and without fatigue. Data were submitted to analysis of variance (FR - one-way ANOVA; BS - two-way ANOVA) and Tukey's test (α= 0.05).
RESULTS: The FR values (mean±SD, in Newtons) were 414.5±83.9 (HC), 621.3±100.3 (RC), and 407.6±109.0 (FG), with RC showing significantly higher FR values (P< 0.05). For BS, there was no statistically significant difference among the materials, with and without fatigue (P> 0.05). The type of material used to obtain the CAD/CAM-customized post-and-cores had a significant effect on the FR, but not on the BS of the specimens. Fatigue did not influence the BS for the tested materials. CLINICAL SIGNIFICANCE: CAD/CAM custom-made esthetic post-and-cores showed good performance relative to fracture resistance and bond strength to root canal dentin walls. The CAD/CAM materials tested could be used as an alternative to restore wide flared root canals in esthetically compromised teeth.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29251451

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  3 in total

Review 1.  Customized Post and Cores Fabricated with CAD/CAM Technology: A Literature Review.

Authors:  Faisal D Al-Qarni
Journal:  Int J Gen Med       Date:  2022-05-06

Review 2.  Efficacy of CAD/CAM Glass Fiber Posts for the Restoration of Endodontically Treated Teeth.

Authors:  Maira Alejandra Gutiérrez; Camilo Alejandro Guerrero; Paula Alejandra Baldion
Journal:  Int J Biomater       Date:  2022-01-21

3.  Effect of Different Post Materials and Adaptability on Fracture Resistance and Fracture Mode in Human Endodontically Treated Teeth.

Authors:  Anutara Bhaktikamala; Wareeratn Chengprapakorn; Pravej Serichetaphongse
Journal:  Int J Dent       Date:  2022-08-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.