Literature DB >> 29247615

How to Adjust Neochordae Length Accurately in Degenerative Mitral Regurgitation.

Jorge Rodriguez-Roda1, Javier Miguelena2, Jose Lopez2, Miren Martin2, Rafael Muñoz2.   

Abstract

We describe a simple technique for the accurate adjustment of polytetrafluoroethylene neochordae length in degenerative mitral regurgitation using the annuloplasty ring's own suture as a reference instead of using sophisticated or less precise maneuvers. Two threads of the annuloplasty ring suture are placed at the level of the mitral valve annulus plane to be used as a reference to tie the neochordae.
Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 29247615     DOI: 10.1016/j.athoracsur.2017.11.033

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Performance and healing of an expanded polytetrafluoroethylene multichordal device at 6 months after repair of mitral leaflet flail in swine.

Authors:  Surendra K Chawla; Robert W M Frater; Mark Cunningham; Muralidhar Padala
Journal:  J Thorac Cardiovasc Surg       Date:  2018-09-25       Impact factor: 5.209

Review 2.  Optimizing P2 Neochordal Length and Stability in Mitral Valve Repair With Use of a Polypropylene Loop.

Authors:  Anil Ozen; Ertekin Utku Unal; Hamdi Mehmet Ozbek; Gorkem Yigit; Hakki Zafer Iscan
Journal:  Tex Heart Inst J       Date:  2020-06-01

3.  Commentary: Functional tricuspid regurgitation: Finally, a ventricular solution to a ventricular problem.

Authors:  Nicolas H Pope; Gorav Ailawadi
Journal:  JTCVS Tech       Date:  2020-06-14
  3 in total