Literature DB >> 2924388

Liver resection using a water jet.

Y Une1, J Uchino, T Horie, Y Sato, K Ogasawara, A Kakita, F Sano.   

Abstract

The water-jet method has been used during hepatic resection. The instrument cuts the hepatic tissue with the high pressure of the fine water flow, while the exposed elastic intrahepatic vessels are spared injury. A comparative study on the water-jet method with the previously employed conventional methods was undertaken. Hepatic resections were performed on 35 patients using the water-jet method. Cirrhosis of the liver was associated with 10 of the 24 patients with hepatocellular carcinoma. An ordinary saline solution was used as the jet, which was projected at a pressure of between 12 kg/cm2 and 20 kg/cm2 through a 0.15/mm-diameter nozzle. A higher jet pressure was needed to cut the fibrotic hepatic parenchyma. In the case of normal liver, the intrahepatic vessels of more than 0.2 mm were well preserved. In most of the cases, the loss of blood when cutting the hepatic parenchyma can be easily reduced with a jet pressure of 15-16 kg/cm2, thus preserving the fine vessels more than 0.2 mm in diameter without injury. When the same pressure was applied in the cutting of a cirrhotic liver, it took much longer time compared to that of a non-cirrhotic normal liver parenchyma. The cut surface was smooth compared to that after using CUSA, although its disadvantages lie in the formation of air bubbles, which obscure the operative field. The controlled projection of a jet of water under optimal pressure may ensure a safe hepatic resection of both normal and cirrhotic livers. Furthermore, because of its uncomplicated form, a wide range of applications can be expected, while the lower cost will also expedite its large-scale use for economic reasons.

Entities:  

Mesh:

Year:  1989        PMID: 2924388     DOI: 10.1007/BF00647245

Source DB:  PubMed          Journal:  Cancer Chemother Pharmacol        ISSN: 0344-5704            Impact factor:   3.333


  2 in total

1.  Histologic evaluation of tissues sectioned by ultrasonically powered instruments (a preliminary report).

Authors:  J W Williams; W J Hodgson
Journal:  Mt Sinai J Med       Date:  1979 Mar-Apr

2.  Resection of the liver with a water jet.

Authors:  D N Papachristou; R Barters
Journal:  Br J Surg       Date:  1982-02       Impact factor: 6.939

  2 in total
  5 in total

1.  Hepatic resection using the harmonic scalpel.

Authors:  H Sugo; Y Mikami; F Matsumoto; H Tsumura; Y Watanabe; K Kojima; S Futagawa
Journal:  Surg Today       Date:  2000       Impact factor: 2.549

2.  Water-jet dissection in renal surgery: experimental study of a new device in the pig.

Authors:  J Hubert; E Mourey; J M Suty; A Coissard; J Floquet; P Mangin
Journal:  Urol Res       Date:  1996

3.  Accidental inclusions following blast injury in esthetical zones: ablation by a hydrosurgery system.

Authors:  Frank Siemers; Karl L Mauss; Eirini Liodaki; Christian Ottomann; Philipp A Bergmann; Peter Mailänder
Journal:  Eplasty       Date:  2012-07-26

4.  Living donor liver resection: a low-tech but highly efficient technique. The Regensburg experience.

Authors:  Aiman Obed; Andreas A Schnitzbauer; Tung-Yu Tsui; Hani Abu Gosh; Anwar Jarrad; Abdulla Bashir; Hans J Schlitt
Journal:  Langenbecks Arch Surg       Date:  2008-01-03       Impact factor: 3.445

5.  Evaluation of a newly developed piezo actuator-driven pulsed water jet system for liver resection in a surviving swine animal model.

Authors:  Chikashi Nakanishi; Toru Nakano; Atsuhiro Nakagawa; Chiaki Sato; Masato Yamada; Naoki Kawagishi; Teiji Tominaga; Noriaki Ohuchi
Journal:  Biomed Eng Online       Date:  2016-01-25       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.