Literature DB >> 29240102

On the "unreasonable" effectiveness of transport of intensity imaging and optical deconvolution.

Timur E Gureyev, Yakov I Nesterets, Alexander Kozlov, David M Paganin, Harry M Quiney.   

Abstract

The effectiveness of reconstructive imaging using the homogeneous transport of intensity equation may be regarded as "unreasonable," because it has been shown to significantly increase signal-to-noise ratio while preserving spatial resolution, compared to equivalent conventional absorption-based imaging techniques at the same photon fluence. We reconcile this surprising behavior by analyzing the propagation of noise in typical in-line holography experiments. This analysis indicates that novel imaging techniques may be designed that produce high signal-to-noise images at low radiation doses without sacrificing spatial resolution.

Year:  2017        PMID: 29240102     DOI: 10.1364/JOSAA.34.002251

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  6 in total

1.  Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction.

Authors:  Luca Brombal; Bruno Golosio; Fulvia Arfelli; Deborah Bonazza; Adriano Contillo; Pasquale Delogu; Sandro Donato; Giovanni Mettivier; Piernicola Oliva; Luigi Rigon; Angelo Taibi; Giuliana Tromba; Fabrizio Zanconati; Renata Longo
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-27

2.  Development of 3D patient-based super-resolution digital breast phantoms using machine learning.

Authors:  Marco Caballo; Christian Fedon; Luca Brombal; Ritse Mann; Renata Longo; Ioannis Sechopoulos
Journal:  Phys Med Biol       Date:  2018-11-12       Impact factor: 3.609

3.  Exploring Compound Eyes in Adults of Four Coleopteran Species Using Synchrotron X-ray Phase-Contrast Microtomography (SR-PhC Micro-CT).

Authors:  Anita Giglio; Maria Luigia Vommaro; Raffaele Giuseppe Agostino; Lai Ka Lo; Sandro Donato
Journal:  Life (Basel)       Date:  2022-05-17

4.  Signal-to-noise, spatial resolution and information capacity of coherent diffraction imaging.

Authors:  Timur E Gureyev; Alexander Kozlov; Yakov I Nesterets; David M Paganin; Andrew V Martin; Harry M Quiney
Journal:  IUCrJ       Date:  2018-09-15       Impact factor: 4.769

5.  Experimental optimization of the energy for breast-CT with synchrotron radiation.

Authors:  Piernicola Oliva; Vittorio Di Trapani; Fulvia Arfelli; Luca Brombal; Sandro Donato; Bruno Golosio; Renata Longo; Giovanni Mettivier; Luigi Rigon; Angelo Taibi; Giuliana Tromba; Fabrizio Zanconati; Pasquale Delogu
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.379

6.  Motion artifacts assessment and correction using optical tracking in synchrotron radiation breast CT.

Authors:  Luca Brombal; Lucia Mariel Arana Peña; Fulvia Arfelli; Renata Longo; Francesco Brun; Adriano Contillo; Francesca Di Lillo; Giuliana Tromba; Vittorio Di Trapani; Sandro Donato; Ralf Hendrik Menk; Luigi Rigon
Journal:  Med Phys       Date:  2021-07-29       Impact factor: 4.506

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.