Literature DB >> 29237991

Survival of HeartMate II Patients Despite Cessation of Anticoagulation - Outcomes and Hemostatic Analysis.

Rashad Zayat1, Mohammad Amen Khattab1, Oliver Grottke2, Markus Honickel2, Andreas Goetzenich1, Ajay Moza1, Christian Stoppe3, Rüdiger Autschbach1, Lachmandath Tewarie1.   

Abstract

BACKGROUND: In long-term left ventricular assist device (LVAD) therapy, recurrent bleeding events may justify cessation of anticoagulation therapy (AT). However, data about THE safety and risks of AT cessation in LVAD patients are scarce.Methods and 
Results: Between 2010 and 2015, 128 patients received a HeartMate II (HMII). Following recurrent bleeding events, we ceased vitamin K antagonist (VKA) therapy in 13 patients (10%) (no-VKA group). To characterize the hemostatic profile, we performed von Willebrand factor (vWF), platelet function (PF), and other hemostatic tests in all HMII patients. The incidence of pump thrombosis (PT), ischemic stroke (IS) and bleeding events in this HMII population was 4.7 %, 6.2% and 36.7%, respectively. Median survival without VKA was 435 days. No cases of PT and only 1 of IS occurred after AT discontinuation. All patients had impaired PF and acquired von Willebrand syndrome (AvWS). However, the vWF collagen-binding activity to antigen ratio before and after VKA cessation was significantly lower in the no-VKA group compared with the HMII population (0.60±0.12 vs. 0.73±0.14, P=0.006). The thrombin-antithrombin III complex (TAT) value was significantly higher in the no-VKA group (P=0.0005).
CONCLUSIONS: We experienced good results with AT cessation in specific HMII patients. The simultaneous onset of AvWS and high TAT values could explain at least in part the low thromboembolic rate in HMII patients without VKA.

Entities:  

Keywords:  Anticoagulation; Bleeding; HeartMate II; Left ventricular assist device; Pump thrombosis

Mesh:

Substances:

Year:  2017        PMID: 29237991     DOI: 10.1253/circj.CJ-17-0897

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  2 in total

1.  Bleeding in critical care associated with left ventricular assist devices: pathophysiology, symptoms, and management.

Authors:  F W G Leebeek; R Muslem
Journal:  Hematology Am Soc Hematol Educ Program       Date:  2019-12-06

2.  Comparison of the Hemocompatibility of an Axial and a Centrifugal Left Ventricular Assist Device in an In Vitro Test Circuit.

Authors:  Patrick Borchers; Patrick Winnersbach; Sandra Kraemer; Christian Beckers; Eva Miriam Buhl; Steffen Leonhardt; Rolf Rossaint; Marian Walter; Thomas Breuer; Christian Bleilevens
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.