Literature DB >> 29235099

Variations from morning to afternoon of middle cerebral and umbilical artery blood flow, and fetal heart rate variability, and fetal characteristics in the normally developing fetus.

Tehila Avitan1, Ari Sanders2, Ursula Brain2,3, Dan Rurak1,3, Tim F Oberlander2,3,4, Ken Lim1,2.   

Abstract

OBJECTIVE: To determine if there are changes in maternal uterine blood flow, fetal brain blood flow, fetal heart rate variability, and umbilical blood flow between morning (AM) and afternoon (PM) in healthy, uncomplicated pregnancies. STUDY
DESIGN: In this prospective study, 68 uncomplicated singleton pregnancies (mean 35 + 0.7 weeks gestation) underwent a standard observational protocol at both 08:00 (AM) and 13:30 (PM) of the same day. This protocol included Doppler measurements of uterine, umbilical, and fetal middle cerebral artery (MCA) volume flow parameters (flow, HR, peak systolic velocity [PSV], PI, and RI) followed by computerized cardiotocography. Standard descriptive statistics, χ2 and t tests were used where appropriate. P < .05 was considered significant.
RESULTS: A significant increase in MCA flow and MCA PSV was observed in the PM compared to the AM. This was accompanied by a fall in MCA resistance. Higher umbilical artery resistance indices were also observed in the PM compared to AM. In contrast, fetal heart rate characteristics, maternal uterine artery Doppler flow and resistance indices did not vary significantly between the AM and PM.
CONCLUSION: In normal pregnancies, variations in fetal cerebral and umbilical blood flow parameters were observed between AM and PM independent of other fetal movements or baseline fetal heart rate. In contrast, uterine flow parameters remained stable across the day. These findings may have implications for the use of serial Doppler parameters used to guide clinical management in high-risk pregnancies.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  Doppler; fetal heart rate; middle cerebral artery; obstetrics; umbilical artery

Mesh:

Year:  2017        PMID: 29235099     DOI: 10.1002/jcu.22569

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  6 in total

1.  Fetal Physiologically Based Pharmacokinetic Models: Systems Information on Fetal Cardiac Output and Its Distribution to Different Organs during Development.

Authors:  Khaled Abduljalil; Xian Pan; Ruth Clayton; Trevor N Johnson; Masoud Jamei
Journal:  Clin Pharmacokinet       Date:  2021-01-24       Impact factor: 6.447

2.  Fetal and Neonatal Middle Cerebral Artery Hemodynamic Changes and Significance under Ultrasound Detection in Hypertensive Disorder Complicating Pregnancy Patients with Different Severities.

Authors:  Pei Zhou; Yi Sun; Yongpan Tan; Yanru An; Xingxing Wang; Lufang Wang
Journal:  Comput Math Methods Med       Date:  2022-06-28       Impact factor: 2.809

3.  Effect of a standardized maternal meal on fetal middle cerebral artery Doppler indices: A single-blinded crossover study.

Authors:  Saba Muneer Zahid; Gun Lisbet Opheim; Tore Henriksen; Trond Melbye Michelsen; Guttorm Haugen
Journal:  PLoS One       Date:  2022-08-04       Impact factor: 3.752

Review 4.  Fetal growth restriction and stillbirth: Biomarkers for identifying at risk fetuses.

Authors:  Victoria J King; Laura Bennet; Peter R Stone; Alys Clark; Alistair J Gunn; Simerdeep K Dhillon
Journal:  Front Physiol       Date:  2022-08-19       Impact factor: 4.755

5.  A maternal meal affects clinical Doppler parameters in the fetal middle cerebral artery.

Authors:  Gun Lisbet Opheim; Manuela Zucknick; Tore Henriksen; Guttorm Haugen
Journal:  PLoS One       Date:  2018-12-31       Impact factor: 3.240

6.  Independent influences of maternal obesity and fetal sex on maternal cardiovascular adaptation to pregnancy: a prospective cohort study.

Authors:  Noor E W D Teulings; Angela M Wood; Ulla Sovio; Susan E Ozanne; Gordon C S Smith; Catherine E Aiken
Journal:  Int J Obes (Lond)       Date:  2020-06-15       Impact factor: 5.095

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.