Literature DB >> 29235042

Rapid Quadrupole-Time-of-Flight Mass Spectrometry Method Quantifies Oxygen-Rich Lignin Compound in Complex Mixtures.

Kelsey S Boes1, Michael S Roberts2, Nelson R Vinueza3.   

Abstract

Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. Graphical Abstract ᅟ.

Entities:  

Keywords:  Bio-oil; Complex mixtures; Diesel; Electrospray ionization; Internal standard; QTOF; Quadrupole-time-of-flight; Quantitation; Tandem mass spectrometry; Triple quadrupole

Year:  2017        PMID: 29235042     DOI: 10.1007/s13361-017-1847-0

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  3 in total

1.  Mechanistic investigation of ionization suppression in electrospray ionization.

Authors:  R King; R Bonfiglio; C Fernandez-Metzler; C Miller-Stein; T Olah
Journal:  J Am Soc Mass Spectrom       Date:  2000-11       Impact factor: 3.109

Review 2.  Ambient ionization MS for bioanalysis: recent developments and challenges.

Authors:  John Takyi-Williams; Chuan-Fa Liu; Kai Tang
Journal:  Bioanalysis       Date:  2015       Impact factor: 2.681

Review 3.  Ion suppression; a critical review on causes, evaluation, prevention and applications.

Authors:  Ambrose Furey; Merisa Moriarty; Vaishali Bane; Brian Kinsella; Mary Lehane
Journal:  Talanta       Date:  2013-04-16       Impact factor: 6.057

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.