| Literature DB >> 29234681 |
Ki-Sun Lee1, Joo-Hee Shin2, Jong-Eun Kim3, Jee-Hwan Kim3, Won-Chang Lee4, Sang-Wan Shin1, Jeong-Yol Lee1.
Abstract
[This corrects the article DOI: 10.1155/2017/1373127.].Entities:
Year: 2017 PMID: 29234681 PMCID: PMC5694984 DOI: 10.1155/2017/7196847
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Mechanical properties of the materials used in the finite element model.
| Materials | Elastic modulus (GPa) | Poisson's ratio | Reference |
|---|---|---|---|
| Cortical bone | 13.7 | 0.30 | [25] |
| Trabecular bone | 1.37 | 0.30 | [25] |
| Periodontal ligament | 0.069 | 0.45 | [25] |
| Dentine | 18.6 | 0.31 | [25] |
| Gutta-percha | 0.00069 | 0.45 | [25] |
| Post cement | 5.0 | 0.30 | [25] |
| Resin core | 20.0 | 0.30 | [25] |
| Fiberglass post | 53.8 | 0.30 | [13] |
| Gold alloy | 95.0 | 0.33 | [14] |
| PEKK | 5.1 | 0.40 | Manufacturer |
| Ceramic crown | 62.0 | 0.30 | [25] |
Flexural strengths for the different component materials of the model.
| Materials | Flexural strength (MPa) | Reference |
|---|---|---|
| Dentine | 212.9 | [25] |
| Post cement | 97 | [25] |
| Resin core | 90 | [25] |
| Fiberglass post | 1242.5 | [13] |
| Gold alloy | 1545.3 | [28] |
| PEKK | 200 | Manufacturer |
| Ceramic crown | 160 | [25] |