Literature DB >> 29233061

Inter- and intra-tester reliability of sensibility testing in healthy individuals.

Tugrul Bulut1, Mesut Tahta1, Ufuk Sener2, Muhittin Sener1.   

Abstract

Static two-point discrimination (S2PD) and Semmes-Weinstein monofilament (SWM) tests are the most widely used tests for evaluation of sensory deterioration. It is a necessity to know the inter- and intra-tester reliability of these tests to determine the suitability of method. Another important point in evaluation of sensory deterioration is whether or not there is a reference point which can be compared with the test results. So, it is important to know the reliability of sensory evaluation tests on the healthy extremities. The aim of this study was to evaluate the inter- and intra-tester reliability of the S2PD and SWM tests applied to the fingers of healthy individuals. One hundred and sixty three healthy fingers from 83 individuals were included into the study. An experienced orthopaedic surgeon and a physiotherapist examined all the individuals separately. The reliability of the S2PD test was found to be little and low. The reliability of the SWM test was determined as low and moderate. The reproducibility scores of both tests were at a poor level. Therefore, in the evaluation of states with sensory deterioration, the use of the healthy contralateral extremities as a standard reference point could be considered unreliable. Prognosis, grading or follow-up of treatment should not be made according to the results of the S2PD and SWM tests only. It would be more correct to use these tests as a diagnostic tool rather than quantitative follow-up for neurological function in pathological conditions.

Keywords:  Healthy subjects; finger; monofilament test; reliability; two-point discrimination test

Mesh:

Year:  2017        PMID: 29233061     DOI: 10.1080/2000656X.2017.1415913

Source DB:  PubMed          Journal:  J Plast Surg Hand Surg        ISSN: 2000-6764


  7 in total

1.  Phase I Safety Trial: Extended Daily Peripheral Sensory Stimulation Using a Wrist-Worn Vibrator in Stroke Survivors.

Authors:  Na Jin Seo; Leah R Enders; Andrew Fortune; Shannon Cain; Amanda A Vatinno; Eli Schuster; Viswanathan Ramakrishnan; Wuwei Feng
Journal:  Transl Stroke Res       Date:  2019-08-23       Impact factor: 6.829

Review 2.  Research reporting in cubital tunnel syndrome studies: an analysis of the literature.

Authors:  Nicholas F Hug; Brandon W Smith; Sarada Sakamuri; Michael Jensen; David A Purger; Robert J Spinner; Thomas J Wilson
Journal:  Acta Neurochir (Wien)       Date:  2022-01-07       Impact factor: 2.216

3.  Using Subthreshold Vibratory Stimulation During Poststroke Rehabilitation Therapy: A Case Series.

Authors:  Amanda A Vatinno; Lucion Hall; Hannah Cox; Alison Fluharty; Catilyn Taylor; Alexandra Wease; Allison Davis; Shannon Cain; Viswanathan Ramakrishnan; Michelle Woodbury; Na Jin Seo
Journal:  OTJR (Thorofare N J)       Date:  2021-09-09

Review 4.  The altering in sensory sensitivity: a current issue of female breast surgery.

Authors:  Tong Zhu; Yi Jiang; Ting Liu; Jinqi Xue; Nan Niu; Jiawen Bu; Mingxin Liu; Caigang Liu; Xudong Zhu; Xi Gu
Journal:  Int J Med Sci       Date:  2022-05-16       Impact factor: 3.642

5.  Aging and the Relationship between Balance Performance, Vestibular Function and Somatosensory Thresholds.

Authors:  Charlotte Johnson; Ann Hallemans; Evi Verbecque; Charlotte De Vestel; Nolan Herssens; Luc Vereeck
Journal:  J Int Adv Otol       Date:  2020-12       Impact factor: 1.017

6.  Wearable vibrotactile stimulation for upper extremity rehabilitation in chronic stroke: clinical feasibility trial using the VTS Glove.

Authors:  Caitlyn E Seim; Steven L Wolf; Thad E Starner
Journal:  J Neuroeng Rehabil       Date:  2021-01-23       Impact factor: 4.262

7.  A Comparison of Changes in Median Nerve Cross-sectional Area Between Endoscopic and Mini-Open Carpal Tunnel Release.

Authors:  William R Smith; David C Hirsch; David O Osei-Hwedieh; Robert J Goitz; John Fowler
Journal:  J Hand Surg Glob Online       Date:  2019-10-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.