Literature DB >> 2923298

Halothane induces depressor responses to noxious stimuli in the rat.

N M Gibbs1, D R Larach, T M Skeehan, H G Schuler.   

Abstract

The effect of halothane on hemodynamic responses to noxious stimuli was investigated in anesthetized male Sprague-Dawley rats. It was found that increasing the end-tidal halothane concentration from sub-MAC to supra-MAC levels was frequently associated with a reversal of the mean arterial pressure response to a noxious stimulus from a pressor response to depressor response. The depressor responses could be produced by noxious stimuli at several sites but were of greatest frequency (100%) and magnitude (up to -80 mmHg) after clamp application at the base of the tail. The depressor responses were often, but not always, accompanied by decreases in heart rate. The correlation coefficient between the changes in heart rate and the changes in mean arterial pressure caused by noxious stimuli was +0.61 (n = 9). The authors further characterized the depressor responses in an additional 18 rats. The depressor responses were not influenced by vagotomy or muscarinic cholinergic blockade and were associated with concurrent decreases in both cardiac output and systemic vascular resistance. The hemodynamic changes associated with the depressor responses were consistent with a centrally mediated withdrawal of sympathetic tone. Knowledge of this effect of halothane on the arterial blood pressure and heart rate responses to noxious stimuli may be important for correctly interpreting animal responses to noxious stimuli in the presence of general anesthetic agents, particularly because animals are frequently used to characterize both the potency and the hemodynamic effects of anesthetic agents. The presence of depressor responses also indicates that mean arterial pressure responses to noxious stimuli cannot be used as a linear index of anesthetic depth in rats anesthetized with halothane.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2923298     DOI: 10.1097/00000542-198903000-00022

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  4 in total

1.  Focal heat stimulation for the determination of the minimum alveolar concentration of halothane in the rabbit.

Authors:  A T Sobair; D F Cottrell; M A Camburn
Journal:  Vet Res Commun       Date:  1997-04       Impact factor: 2.459

2.  Types of skin afferent fibers and spinal opioid receptors that contribute to touch-induced inhibition of heart rate changes evoked by noxious cutaneous heat stimulation.

Authors:  Nobuhiro Watanabe; Mathieu Piché; Harumi Hotta
Journal:  Mol Pain       Date:  2015-02-12       Impact factor: 3.395

3.  Heart Rate Changes in Response to Mechanical Pressure Stimulation of Skeletal Muscles Are Mediated by Cardiac Sympathetic Nerve Activity.

Authors:  Nobuhiro Watanabe; Harumi Hotta
Journal:  Front Neurosci       Date:  2017-01-10       Impact factor: 4.677

4.  Local anesthesia in piglets undergoing castration-A comparative study to investigate the analgesic effects of four local anesthetics on the basis of acute physiological responses and limb movements.

Authors:  Anna M Saller; Julia Werner; Judith Reiser; Steffanie Senf; Pauline Deffner; Nora Abendschön; Christine Weiß; Johannes Fischer; Andrea Schörwerth; Regina Miller; Yury Zablotski; Shana Bergmann; Michael H Erhard; Mathias Ritzmann; Susanne Zöls; Christine Baumgartner
Journal:  PLoS One       Date:  2020-07-30       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.