Literature DB >> 2923294

Measurement of stroke volume with three-dimensional transesophageal ultrasonic scanning: comparison with thermodilution measurement.

R W Martin1, G Bashein.   

Abstract

The accuracy of measuring cardiac stroke volume with a new transesophageal phased array ultrasonic probe was investigated in 10 dogs. The method involved scanning the heart to obtain serial images covering the entire left ventricular cavity at end-expiration. An off-line computer analysis of the images was used to form three-dimensional reconstructions of the left ventricular cavity at end-diastole and end-systole, from which stroke volume was determined. Comparison with stroke volume determined by thermodilution during a wide range of hemodynamic conditions gave the following results for least-squares regression on 57 determinations (with the 95% confidence limits in parentheses): slope 0.95 (0.842-1.06), ordinate intercept 2.1 (2.0-2.2) ml, standard error of the estimate 4.1 ml, and correlation coefficient of 0.92 (0.87-0.95). Histologic examination of sections of esophagus surrounding the tip of the probe in nine dogs demonstrated minimal trauma to the esophageal wall, with eight specimens described as normal and one showing mild inflammation. The authors conclude that three-dimensional reconstruction of the left ventricular cavity from multiple transesophageal images offers a safe and accurate, although presently tedious, method for determining stroke volume.

Entities:  

Mesh:

Year:  1989        PMID: 2923294     DOI: 10.1097/00000542-198903000-00017

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  4 in total

1.  Study on three dimensional reconstruction of transesophageal echocardiographic images.

Authors:  Z A Li; X F Wang; P Lu; G Hu; L H Zheng; Y Yang
Journal:  J Tongji Med Univ       Date:  1995

2.  Three-dimensional transesophageal echocardiography for depiction of regional left-ventricular performance: initial results and future directions.

Authors:  G Bashein; F H Sheehan; M L Nessly; P R Detmer; R W Martin
Journal:  Int J Card Imaging       Date:  1993-06

3.  Quantitative three dimensional echocardiography in patients with pulmonary hypertension and compressed left ventricles: comparison with cross sectional echocardiography and magnetic resonance imaging.

Authors:  H D Apfel; Z Shen; A S Gopal; V Vangi; D Solowiejczyk; K Altmann; R J Barst; L M Boxt; L D Allan; D L King
Journal:  Heart       Date:  1996-10       Impact factor: 5.994

4.  Dynamic three-dimensional echocardiography with a computed tomography imaging probe: initial clinical experience with transthoracic application in infants and children with congenital heart defects.

Authors:  M Vogel; S Lösch
Journal:  Br Heart J       Date:  1994-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.