Literature DB >> 29232609

Influence of direct and sequential extraction methodology on metabolic profiling.

K M Maria John1, James Harnly1, Devanand Luthria2.   

Abstract

A systematic comparison was made of the detected metabolite profiles for two plant materials (black beans and soybeans) and a dietary supplement (black cohosh) extracted using sequential (hexane, ethyl acetate, and 50% aqueous methanol) and direct extraction with three solvent systems (80% aqueous methanol, methanol/chloroform/water (2.5:1:1, v/v/v) and water). Extracts were analyzed by LC-MS (without derivatization) and GC-FID (with BSTFA/TMCS derivatizations). For sequential extraction, HPLC-UV and BSTFA/TMCS-derivatized GC-FID detection were more responsive to the polar molecules with a rough distribution of 10%, 10%, and 80% of the total signals in hexane, ethyl acetate, and 50% aqueous methanol, respectively. With HPLC-MS detection, the distribution of signals was more balanced, roughly 40%, 30%, and 30% for the same extracts (hexane, ethyl acetate, and 50% aqueous methanol). For direct extraction, HPLC-UV and BSTFA/TMCS-derivatized 4GC-FID provided signals between 60% and 150% of the total sequential extracted signals. The overlap of signals for the 3 sequential extracts ranged from 1% to 3%. The overlap of the signals for direct extraction with the total for sequential extraction ranged from 15% to 98%. With HPLC-MS detection, signals varied from 30% to 40% of the total signals for sequential extraction. Multivariate analysis showed that the components for the sequential and direct extracts were statistically different. However, each extract, sequential or direct, allowed discrimination between the 3 plant materials. Published by Elsevier B.V.

Entities:  

Keywords:  GC–MS; HPLC-UV; HPLC–MS; Metabolic profiling; Multivariate analysis; Sequential and direct extractions; With and without derivatization

Mesh:

Substances:

Year:  2017        PMID: 29232609     DOI: 10.1016/j.jchromb.2017.12.005

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  A Comparative Study of Diospyros malabarica (Gaub) Extracts in Various Polarity-Dependent Solvents for Evaluation of Phytoconstituents and Biological Activities.

Authors:  Zohra Zreen; Amjad Hameed; Shumaila Kiran; Tahir Farooq; Mohammed Suleiman Zaroog
Journal:  Biomed Res Int       Date:  2022-06-25       Impact factor: 3.246

2.  Compositional Analysis of Non-Polar and Polar Metabolites in 14 Soybeans Using Spectroscopy and Chromatography Tools.

Authors:  Raghavendhar R Kotha; Savithiry Natarajan; Dechun Wang; Devanand L Luthria
Journal:  Foods       Date:  2019-11-07

Review 3.  Biostimulants for Plant Growth and Mitigation of Abiotic Stresses: A Metabolomics Perspective.

Authors:  Lerato Nephali; Lizelle A Piater; Ian A Dubery; Veronica Patterson; Johan Huyser; Karl Burgess; Fidele Tugizimana
Journal:  Metabolites       Date:  2020-12-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.