Literature DB >> 29229418

A Biomechanical Evaluation of Various Double Krackow Suture Techniques for Soft-Tissue Graft Fixation.

Chih-Kai Hong1, Cheng-Li Lin2, Fa-Chuan Kuan3, Ping-Hui Wang4, Ming-Long Yeh5, Wei-Ren Su6.   

Abstract

PURPOSE: The purpose of this study was to compare the biomechanical properties among the different double Krackow suture techniques for tendon graft fixation.
METHODS: Thirty porcine flexor profundus tendons were randomly divided into 3 groups of 10 specimens each. Three different double Krackow suture techniques were evaluated, namely, the McKeon's double Krackow (MDK) suture, Wilson's double Krackow (WDK) suture, and Ostrander's modified Krackow (OMK) suture. All suture configurations were completed with a braided nonabsorbable suture. Each suture-tendon construct was pretensioned to 100 N for 3 cycles, cyclically loaded from 50 to 200 N for 200 cycles, and then finally loaded to failure. Elongation after cyclic loading, ultimate load to failure, and the mode of failure were recorded for each specimen.
RESULTS: There were significant differences in elongation after cyclic loading among the MDK suture (7.9 ± 3.6 mm, 14% ± 6%), WDK suture (11.6 ± 2.2 mm, 22% ± 3%), and OMK suture (9.6 ± 3.3 mm, 17% ± 6%; P = .018). In addition, although the post hoc analysis showed that elongation after cyclic loading in the MDK suture was significantly less than the WDK suture (P = .004), ultimate failure load and cross-sectional area were not significantly different across the 3 groups.
CONCLUSIONS: In this porcine in vitro biomechanical study, the MDK suture had significantly smaller elongation after cyclic loading than the WDK suture; however, high elongation values may have a potential for risk of clinical laxity. The ultimate failure load was not different across the MDK, WDK, and OMK sutures. CLINICAL RELEVANCE: Smaller elongation during cyclic loading in a suture-tendon construct represents a lower possibility of tendon graft loosening after ligament reconstruction surgery. The double Krackow suture techniques are attractive options for tendon graft fixation in ligament reconstruction, and the MDK suture could possibly be the optimal choice among the double Krackow suture techniques.
Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 29229418     DOI: 10.1016/j.arthro.2017.09.025

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  3 in total

1.  The Biomechanical Properties of a High-Tensile Strength Tape for Tendon Graft Fixation Using the Krackow Configuration.

Authors:  Chih-Kai Hong; Kai-Lan Hsu; Fa-Chuan Kuan; Yueh Chen; Chen-Hao Chiang; Ming-Long Yeh; Miin-Jye Wen; Wei-Ren Su
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-07-09

2.  Continuous-Loop Tape Technique Has Greater Stiffness and Less Elongation Compared With Tied-Suture Fixation of Full-Thickness All-Soft Tissue Quadriceps Tendon Autografts.

Authors:  Christopher M Gibbs; Philipp W Winkler; Robert T Tisherman; Calvin K Chan; Theresa A Diermeier; Richard E Debski; Volker Musahl
Journal:  Orthop J Sports Med       Date:  2021-11-11

3.  Biomechanical Comparison of a Novel Multiplanar, Perpendicular Whipstitch With the Krackow Stitch and Standard Commercial Whipstitch.

Authors:  Stefano Muscatelli; Kempland C Walley; Conor S Daly-Seiler; Joseph A Greenstein; Aaron Sciascia; David P Patterson; Michael T Freehill
Journal:  Orthop J Sports Med       Date:  2022-08-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.