Literature DB >> 29227279

Drug-eluting balloon: design, technology and clinical aspects.

Meenasree Bukka1, Poorna Jyothi Rednam, Mukty Sinha.   

Abstract

A drug-eluting balloon is a non-stent technology in which the effective homogenous delivery of anti-proliferative drugs is processed by the vessel wall through an inflated balloon. This is done to restore luminal vascularity in order to treat atherosclerosis, in-stent restenosis and reduce the risk of late thrombosis without implanting a permanent foreign object. The balloon technology relies on the concept of targeted drug delivery, which helps in the rapid healing of the vessel wall and prevents the proliferation of smooth muscle cells. Several drug eluting devices in the form of coated balloons are currently in clinical use, namely DIOR®, PACCOCATH®, SeQuent®Please and IN.PACT™. The device varies in terms of the material used for making the balloon, the coating techniques, the choice of coated drug and the release pattern of the drug at the site. This review gives an insight into the evolution, rationale and comparison of the marketed drug-eluting balloons. Here, different coating techniques have been analysed for the application and critical analysis of available DEB technologies, and a technical comparison has been done.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29227279     DOI: 10.1088/1748-605X/aaa0aa

Source DB:  PubMed          Journal:  Biomed Mater        ISSN: 1748-6041            Impact factor:   3.715


  5 in total

Review 1.  Targeted delivery of therapeutic agents to the heart.

Authors:  Susmita Sahoo; Taro Kariya; Kiyotake Ishikawa
Journal:  Nat Rev Cardiol       Date:  2021-01-26       Impact factor: 32.419

Review 2.  Patency of ePTFE Arteriovenous Graft Placements in Hemodialysis Patients: Systematic Literature Review and Meta-Analysis.

Authors:  Ronald J Halbert; Gina Nicholson; Robert J Nordyke; Alison Pilgrim; Laura Niklason
Journal:  Kidney360       Date:  2020-10-15

Review 3.  Drug-Eluting Stents and Balloons-Materials, Structure Designs, and Coating Techniques: A Review.

Authors:  I Rykowska; I Nowak; R Nowak
Journal:  Molecules       Date:  2020-10-11       Impact factor: 4.411

4.  Efficacy and safety of drug-coated balloons according to coronary vessel size. A report from the BASKET-SMALL 2 trial.

Authors:  Ahmed Farah; Mohamed Elgarhy; Marc-Alexander Ohlow; Jochen Wohrle; Norman Mangner; Sven Möbius-Winkler; Marco Cattaneo; Nicole Gilgen; Bruno Scheller; Raban Jeger
Journal:  Postepy Kardiol Interwencyjnej       Date:  2022-08-19       Impact factor: 1.065

5.  Favorable Vasomotor Function after Drug-Coated Balloon-Only Angioplasty of De Novo Native Coronary Artery Lesions.

Authors:  Sunwon Kim; Jong-Seok Lee; Yong-Hyun Kim; Jin-Seok Kim; Sang-Yup Lim; Seong Hwan Kim; Minjung Kim; Jeong-Cheon Ahn; Woo-Hyuk Song
Journal:  J Clin Med       Date:  2022-01-07       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.