Literature DB >> 29226658

Application of Commutable ERM-DA474/IFCC for Harmonization of C-reactive Protein Measurement Using Five Analytical Assays.

Chunying Wu, Shunli Zhang, Wei Liu, Jie Zeng, Tingting Zhao, Yuhong Yue, Rui Zhang, Huaian Ma, Qingtao Wang.   

Abstract

BACKGROUND: ERM-DA474/IFCC has been used as a reference material for C-reactive protein (CRP) since 2012. However, the commutabilities and the capacity for harmonizing CRP results of the material and its dilutions have not yet been reported. In this study, we aimed to evaluate the harmonization of CRP results using commutable ERM-DA474/IFCC.
METHODS: Twenty-one serum samples were collected and split into five vials. The samples were then analyzed using five popular assays (Siemens BN II, Beckman Immage 800, Roche, Diasys, and Leadman). ERM-DA474/IFCC and four dilutions of healthy human serum containing low levels of CRP were also analyzed using the five assays described above. Commutability was assessed using the Roche, Diasys, and Leadman assays. Clinical sample results from assays were recalibrated based on ERM-DA474/IFCC and its dilutions.
RESULTS: There were significant variations among the five assays for CRP measurement. The slopes ranged from 0.60 to 1.60, and the BN II and Leadman assays showed significant negative and positive systemic biases, respectively. ERM-DA474/IFCC and its dilutions exhibited commutability among the three assays. After recalibration, the slope was reduced to 0.76 - 1.27.
CONCLUSIONS: Harmonization was not ideal for CRP measurement. ERM-DA474/IFCC may play a role in improving harmonization for CRP measurement.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29226658     DOI: 10.7754/Clin.Lab.2017.170626

Source DB:  PubMed          Journal:  Clin Lab        ISSN: 1433-6510            Impact factor:   1.138


  3 in total

1.  A Novel Method for Quantitative Analysis of C-Reactive Protein Lateral Flow Immunoassays Images via CMOS Sensor and Recurrent Neural Networks.

Authors:  Min Jing; Donal Mclaughlin; Sara E Mcnamee; Shasidran Raj; Brian Mac Namee; David Steele; Dewar Finlay; James Mclaughlin
Journal:  IEEE J Transl Eng Health Med       Date:  2021-11-23       Impact factor: 3.316

2.  Epitope mapping of antibodies in C-reactive protein assay kits by hydrogen-deuterium exchange mass spectrometry explains differential results across kits.

Authors:  Haofeng Sun; Jianyi Liu; Peng Xiao; Yi Zhou; Hongmei Li; Min Shen; Keqi Sun; Xiaojian Wang; Min Zhou; Dewei Song
Journal:  Anal Bioanal Chem       Date:  2022-04-07       Impact factor: 4.142

3.  Evaluation of INSTAND e.V.'s external quality assessment for C-reactive protein and procalcitonin.

Authors:  Nathalie Wojtalewicz; Ingo Schellenberg; Klaus-Peter Hunfeld
Journal:  PLoS One       Date:  2019-08-16       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.