Literature DB >> 29223405

Polished, Collarless, Tapered, Cemented Stems for Primary Hip Arthroplasty May Exhibit High Rate of Periprosthetic Fracture at Short-Term Follow-Up.

Trevor Scott1, Anthony Salvatore1, Pauline Woo1, Yuo-Yu Lee1, Eduardo A Salvati1, Alejandro Gonzalez Della Valle1.   

Abstract

BACKGROUND: Cemented stems are designed to follow 1 of 2 principles of fixation: composite beams or slide taper. Stems in the latter category have a collarless, polished, tapered (CPT) design and subside into the cement mantle, creating hoop stresses. We compared the rate of periprosthetic fracture (PPF) of stem designed with these 2 principles of fixation. In addition, we examined radiographic factors that may predispose to the development of PPF.
METHODS: We retrospectively reviewed all patients who underwent primary THA by a single surgeon using highly polished cemented stems. PPF rates were compared between CPT stems (follow-up, 21 months; standard deviation [SD], 22) and composite beam stems (follow-up, 21.7 months; SD, 26). Demographic data were compared between patients with and without a PPF. Three preoperative radiographic parameters (canal bone ratio [CBR], canal-calcar ratio, and canal flare index), stem alignment, and cement mantle were compared in match-paired patients with and without a PPF (1:34).
RESULTS: Seven of 1460 THA patients developed a PPF (0.479%); 4 hips of 185 with a CPT stem (2.2%); and 3 of 1275 hips with a composite beam stem (0.23%; P = .0064). Three of the 4 PPFs in the CPT group and none in the composite beam group were classified as Vancouver B2. The CBR in patients with a PPF was 0.50 (SD, 0.07) and 0.43 (SD, 0.07) in the match cohort of hips without PPF (P = .013).
CONCLUSION: CPT stems may be associated with a higher risk of PPF that often require reoperation. An increased CBR may be a risk factor for postoperative PPF.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cemented total hip arthroplasty; periprosthetic fracture; polished tapered stem; stem design; surface finish

Mesh:

Substances:

Year:  2017        PMID: 29223405     DOI: 10.1016/j.arth.2017.11.003

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

Review 1.  Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review.

Authors:  Kwaku Baryeh; David H Sochart
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-20       Impact factor: 3.067

2.  The race for the classification of proximal periprosthetic femoral fractures : Vancouver vs Unified Classification System (UCS) - a systematic review.

Authors:  Clemens Schopper; Matthias Luger; Günter Hipmair; Bernhard Schauer; Tobias Gotterbarm; Antonio Klasan
Journal:  BMC Musculoskelet Disord       Date:  2022-03-23       Impact factor: 2.362

  2 in total