Literature DB >> 29223233

Outcomes of retreatment after hyperopic laser in situ keratomileusis.

Andreas Frings1, Elisa Intert2, Johannes Steinberg2, Vasyl Druchkiv2, Stephan J Linke2, Toam Katz2.   

Abstract

PURPOSE: To evaluate the efficacy, predictability, and safety of laser in situ keratomileusis (LASIK) retreatment in eyes with hyperopia.
SETTING: Multicenter refractive surgery centers and University Hospital, Germany.
DESIGN: Retrospective case series.
METHODS: This multicenter study included hyperopic patients with a preoperative difference between cycloplegic and manifest refraction of 1.00 diopter (D) or less who had LASIK retreatment based on manifest refraction. The refractive outcome was analyzed according to standard graphs for reporting the efficacy, predictability, and safety of refractive surgery.
RESULTS: One hundred thirteen eyes of 113 consecutive hyperopic patients were enrolled. Efficacy (P < .001) and safety (P = .004) were statistically significantly improved by retreatment without being negatively influenced by preoperative manifest spherical equivalent (SE), manifest cylinder, or keratometry. In cases still showing a trend toward undercorrection, retreatment resulted in 88 eyes (78.0%) being within ±0.50 D of the attempted correction. The optical zone (OZ) diameter of the retreatment did not correlate with efficacy, predictability, or safety.
CONCLUSIONS: Retreatment after hyperopic LASIK resulted in high efficacy, predictability, and safety outcomes. The efficacy and safety of the retreatment were not affected by preoperative manifest SE, manifest cylinder, keratometry, or OZ diameter.
Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29223233     DOI: 10.1016/j.jcrs.2017.08.014

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

1.  Long-term safety of laser in situ keratomileusis in eyes with thin corneas: 5-year follow-up.

Authors:  Yao-Wen Song; Rui He; Jack X Ma; Douglas D Koch; Li Wang
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

2.  Treatment of High Astigmatism with WaveLight Allegretto Eye-Q Excimer Laser Platform.

Authors:  Alma Biscevic; Maja Bohac; Melisa Ahmedbegovic Pjano; Senad Grisevic; Sudi Patel; Ajla Pidro
Journal:  Acta Inform Med       Date:  2019-09

3.  Laser-Assisted In Situ Keratomileusis (LASIK) Enhancement for Residual Refractive Error after Primary LASIK.

Authors:  Majid Moshirfar; Noor F Basharat; Nour Bundogji; Emilie L Ungricht; Ines M Darquea; Matthew E Conley; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.