Wavelength selection for portable noninvasive blood component measurement system based on spectral difference coefficient and dynamic spectrum.

Ximeng Feng1, Gang Li1, Haixia Yu1, Shaohui Wang2, Xiaoqing Yi1, Ling Lin3.   

Abstract

Noninvasive blood component analysis by spectroscopy has been a hotspot in biomedical engineering in recent years. Dynamic spectrum provides an excellent idea for noninvasive blood component measurement, but studies have been limited to the application of broadband light sources and high-resolution spectroscopy instruments. In order to remove redundant information, a more effective wavelength selection method has been presented in this paper. In contrast to many common wavelength selection methods, this method is based on sensing mechanism which has a clear mechanism and can effectively avoid the noise from acquisition system. The spectral difference coefficient was theoretically proved to have a guiding significance for wavelength selection. After theoretical analysis, the multi-band spectral difference coefficient-wavelength selection method combining with the dynamic spectrum was proposed. An experimental analysis based on clinical trial data from 200 volunteers has been conducted to illustrate the effectiveness of this method. The extreme learning machine was used to develop the calibration models between the dynamic spectrum data and hemoglobin concentration. The experiment result shows that the prediction precision of hemoglobin concentration using multi-band spectral difference coefficient-wavelength selection method is higher compared with other methods.
Copyright © 2017 Elsevier B.V. All rights reserved.

Keywords:  Dynamic spectrum; Noninvasive spectrum; Spectral difference coefficient; Wavelength selection

Mesh:

Substances:

Year:  2017        PMID: 29223052     DOI: 10.1016/j.saa.2017.10.063

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  2 in total

1.  Quantitative estimation of wastewater quality parameters by hyperspectral band screening using GC, VIP and SPA.

Authors:  Zheng Xing; Junying Chen; Xiao Zhao; Yu Li; Xianwen Li; Zhitao Zhang; Congcong Lao; Haifeng Wang
Journal:  PeerJ       Date:  2019-12-12       Impact factor: 2.984

2.  Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations.

Authors:  Md Kamrul Hasan; Md Hasanul Aziz; Md Ishrak Islam Zarif; Mahmudul Hasan; Mma Hashem; Shion Guha; Richard R Love; Sheikh Ahamed
Journal:  JMIR Mhealth Uhealth       Date:  2021-04-08       Impact factor: 4.773

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.