Literature DB >> 29222338

Blood Sample Transportation by Pneumatic Transportation Systems: A Systematic Literature Review.

Mads Nybo1, Merete E Lund2, Kjell Titlestad2, Christian U Maegaard3.   

Abstract

BACKGROUND: Pneumatic transportation systems (PTSs) are increasingly used for transportation of blood samples to the core laboratory. Many studies have investigated the impact of these systems on different types of analyses, but to elucidate whether PTSs in general are safe for transportation of blood samples, existing literature on the subject was systematically assessed.
METHODS: A systematic literature review was conducted following the preferred reporting items for systematic reviews and metaanalyses (PRISMA) Statement guidelines to gather studies investigating the impact of PTS on analyses in blood samples. Studies were extracted from PubMed and Embase. The search period ended November 2016.
RESULTS: A total of 39 studies were retrieved. Of these, only 12 studies were conducted on inpatients, mainly intensive care unit patients. Blood gases, hematology, and clinical chemistry were well investigated, whereas coagulation, rotational thromboelastometry, and platelet function in acutely ill patients were addressed by only 1 study each. Only a few parameters were affected in a clinically significant way (clotting time parameter in extrinsic system thromboelastometry, pO2 in blood gas, multiplate analysis, and the hemolysis index).
CONCLUSIONS: Owing to their high degree of heterogeneity, the retrieved studies were unable to supply evidence for the safety of using PTSs for blood sample transportation. In consequence, laboratories need to measure and document the actual acceleration forces in their existing PTS, instituting quality target thresholds for these measurements such as acceleration vector sums. Computer modeling might be applied to the evaluation of future PTS installations. With the increasing use of PTS, a harmonized, international recommendation on this topic is warranted.
© 2017 American Association for Clinical Chemistry.

Entities:  

Mesh:

Year:  2017        PMID: 29222338     DOI: 10.1373/clinchem.2017.280479

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  5 in total

1.  Effect of Pneumatic Tubing System Transport on Platelet Apheresis Units.

Authors:  Jevgenia Zilberman-Rudenko; Frank Z Zhao; Stephanie E Reitsma; Annachiara Mitrugno; Jiaqing Pang; Joseph J Shatzel; Beth Rick; Christina Tyrrell; Wohaib Hasan; Owen J T McCarty; Martin A Schreiber
Journal:  Cardiovasc Eng Technol       Date:  2018-05-21       Impact factor: 2.495

2.  Pathologic Blood Samples Tolerate Exposure to Vibration and High Turbulence in Simulated Drone Flights, but Plasma Samples Should be Centrifuged After Flight.

Authors:  Karl Arne Johannessen; Nina Kristin Steen Wear; Karin Toska; Morten Hansbo; Jens Petter Berg; Erik Fosse
Journal:  IEEE J Transl Eng Health Med       Date:  2021-01-20       Impact factor: 3.316

3.  New Solutions for the Sample Transport and Results Delivery: A Digital Lab.

Authors:  Damien Gruson
Journal:  EJIFCC       Date:  2018-11-07

Review 4.  Errors within the total laboratory testing process, from test selection to medical decision-making - A review of causes, consequences, surveillance and solutions.

Authors:  Cornelia Mrazek; Giuseppe Lippi; Martin H Keppel; Thomas K Felder; Hannes Oberkofler; Elisabeth Haschke-Becher; Janne Cadamuro
Journal:  Biochem Med (Zagreb)       Date:  2020-06-15       Impact factor: 2.313

5.  Triple apheresis platelet concentrate quality after pneumatic tube system, conveyor box, and courier transport: An observational study.

Authors:  Lena Reichert; Stefan Wallner; Ralph Burkhardt; Robert Offner; Norbert Ahrens; Viola Hähnel
Journal:  Health Sci Rep       Date:  2022-04-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.