Literature DB >> 29221107

Interferometric synthetic aperture microscopy for extended focus optical coherence microscopy.

Séverine Coquoz, Arno Bouwens, Paul J Marchand, Jérôme Extermann, Theo Lasser.   

Abstract

Optical coherence microscopy (OCM) is an interferometric technique providing 3D images of biological samples with micrometric resolution and penetration depth of several hundreds of micrometers. OCM differs from optical coherence tomography (OCT) in that it uses a high numerical aperture (NA) objective to achieve high lateral resolution. However, the high NA also reduces the depth-of-field (DOF), scaling with 1/NA2. Interferometric synthetic aperture microscopy (ISAM) is a computed imaging technique providing a solution to this trade-off between resolution and DOF. An alternative hardware method to achieve an extended DOF is to use a non-Gaussian illumination. Extended focus OCM (xfOCM) uses a Bessel beam to obtain a narrow and extended illumination volume. xfOCM detects back-scattered light using a Gaussian mode in order to maintain good sensitivity. However, the Gaussian detection mode limits the DOF. In this work, we present extended ISAM (xISAM), a method combining the benefits of both ISAM and xfOCM. xISAM uses the 3D coherent transfer function (CTF) to generalize the ISAM algorithm to different system configurations. We demonstrate xISAM both on simulated and experimental data, showing that xISAM attains a combination of high transverse resolution and extended DOF which has so far been unobtainable through conventional ISAM or xfOCM individually.

Entities:  

Year:  2017        PMID: 29221107     DOI: 10.1364/OE.25.030807

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  4 in total

1.  Volumetric optical coherence microscopy with a high space-bandwidth-time product enabled by hybrid adaptive optics.

Authors:  Siyang Liu; Jeffrey A Mulligan; Steven G Adie
Journal:  Biomed Opt Express       Date:  2018-06-15       Impact factor: 3.732

2.  Extended focal depth Fourier domain optical coherence microscopy with a Bessel-beam - LP02 mode - from a higher order mode fiber.

Authors:  Dipankar Sen; Anton Classen; Alma Fernández; Lars Grüner-Nielsen; Holly C Gibbs; Shahriar Esmaeili; Philip Hemmer; Andrius Baltuska; Alexei V Sokolov; Rainer A Leitgeb; Aart J Verhoef
Journal:  Biomed Opt Express       Date:  2021-11-05       Impact factor: 3.732

3.  Deep learning extended depth-of-field microscope for fast and slide-free histology.

Authors:  Lingbo Jin; Yubo Tang; Yicheng Wu; Jackson B Coole; Melody T Tan; Xuan Zhao; Hawraa Badaoui; Jacob T Robinson; Michelle D Williams; Ann M Gillenwater; Rebecca R Richards-Kortum; Ashok Veeraraghavan
Journal:  Proc Natl Acad Sci U S A       Date:  2020-12-14       Impact factor: 11.205

4.  Optical coherence refraction tomography.

Authors:  Kevin C Zhou; Ruobing Qian; Simone Degan; Sina Farsiu; Joseph A Izatt
Journal:  Nat Photonics       Date:  2019-08-19       Impact factor: 38.771

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.