Literature DB >> 29217274

Contact wear of artificial denture teeth.

Verena Preis1, Sebastian Hahnel2, Michael Behr2, Martin Rosentritt2.   

Abstract

PURPOSE: High wear resistance of denture teeth preserves good occlusal relationship and sufficient parafunctional stability. This in-vitro investigation aimed to determine and compare the wear performance of different artificial denture teeth.
METHODS: Denture teeth of fifteen commercial products (n=8/group) were loaded in a pin-on-block design using steatite antagonists (d=3mm). Cyclic loading (50 N) was applied for 120,000 loadings (f=1.2Hz) with simultaneous thermal cycling (distilled water, 5°C/55°C, 2min/cycle). A loading cycle consisted of a vertical 1mm impact and a subsequent lateral 1mm sliding movement. Worn areas were digitalized (3-D-laser-scanning-microscope). Maximum and mean wear depth and surface roughness were determined and statistically compared (one-way Anova, Tukey-HSD test, α=0.05). Worn surfaces and cut specimens were investigated with scanning electron microscopy (SEM).
RESULTS: Maximum wear varied between 475.1μm and 1232.2μm. Mean wear was between 241.1μm and 753.6μm with significant differences (p<0.001) between individual materials. Mean and maximum wear showed a significant correlation (Pearson's correlation coefficient: 0.942). Surface roughness increased between unworn to worn surface by 1.2μm (Ra, p=0.387) and by 41.7μm (Rz, p=0.000). All materials provided round or drop-shaped wear traces. Superficial analysis showed no cracks, chipping or fractures in the worn areas. Detailed evaluation of cut specimens with SEM exposed cracks on the bottom of the wear traces.
CONCLUSIONS: Denture teeth showed significantly different in-vitro wear performance and increased roughness in the wear trace. Differences may be attributed to the composition of the materials, regarding both filler and polymer structure. The selection of teeth might contribute to enhanced in-vivo performance of the denture.
Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Chewing simulation; Composite teeth; Denture teeth; Resin-based teeth; Wear resistance

Mesh:

Substances:

Year:  2017        PMID: 29217274     DOI: 10.1016/j.jpor.2017.11.001

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  3 in total

1.  Composite 3D printing of biomimetic human teeth.

Authors:  A J Cresswell-Boyes; G R Davis; M Krishnamoorthy; D Mills; A H Barber
Journal:  Sci Rep       Date:  2022-05-12       Impact factor: 4.996

2.  Impact of Nanoparticles Additions on the Strength of Dental Composite Resin.

Authors:  Emad Azmy; Mohamed Reda Zaki Al-Kholy; Mohamed Fattouh; Laila Mohamed Mohamed Kenawi; Mohamed Ahmed Helal
Journal:  Int J Biomater       Date:  2022-07-05

3.  A comparative evaluation of wear resistance of three types of artificial acrylic teeth after removing the glaze layer.

Authors:  Samaneh Abbasi; Saeed Nikanjam; Arash Shishehian; Sara Khazaei; Farnoush Fotovat; Nilofar Heydar Pana
Journal:  Dent Res J (Isfahan)       Date:  2022-07-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.