Literature DB >> 2921428

The optimum placement-site of the electrode in electric pulp testing of the 12 anterior teeth.

I B Bender1, M A Landau, S Fonsecca, H O Trowbridge.   

Abstract

The present study of 2,387 recordings of 12 anterior teeth in 53 patients indicates that the incisal edge is the optimal placement-site for the electric pulp tester to determine the lowest response threshold. The results show significant individual variations in the lowest threshold responses of the cervical-third, middle-third, incisal one-third, and incisal edge sites on a tooth, with a confidence level of 99%, according to the analysis of variance. The maxillary teeth gave a higher response threshold than the mandibular teeth and different types of teeth (canines and incisors) had statistically significant different response thresholds. The application of the electric pulp tester to the incisal-edge region with exposed dentin produced the most significant decrease in the threshold response.

Entities:  

Mesh:

Year:  1989        PMID: 2921428     DOI: 10.14219/jada.archive.1989.0096

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  14 in total

1.  Comparative clinical evaluation of different epinephrine concentrations in 4% articaine for dental local infiltration anesthesia.

Authors:  P W Kämmerer; J Seeling; A Alshihri; M Daubländer
Journal:  Clin Oral Investig       Date:  2013-06-06       Impact factor: 3.573

Review 2.  Magnetic resonance imaging in endodontics: a literature review.

Authors:  Yoshiko Ariji; Eiichiro Ariji; Misako Nakashima; Koichiro Iohara
Journal:  Oral Radiol       Date:  2017-08-18       Impact factor: 1.852

3.  The use of dental pulp tests in children with dental trauma: a national survey of the British Society of Paediatric Dentistry's members.

Authors:  N Ghouth; M S Duggal; H Nazzal
Journal:  Br Dent J       Date:  2019-02-01       Impact factor: 1.626

4.  Evaluation of the Response to Pulpal Sensibility Tests (Cold, EPT) in Anemic and Healthy Women.

Authors:  Maryam Kazemipoor; Mohammad Kazem Vatanchian; Sara Jambarsang; Fatemeh Owlia
Journal:  Int J Dent       Date:  2022-06-18

5.  Dental pulp testing: a review.

Authors:  Eugene Chen; Paul V Abbott
Journal:  Int J Dent       Date:  2009-11-12

6.  Comparison of effectiveness of 4% articaine associated with 1: 100,000 or 1: 200,000 epinephrine in inferior alveolar nerve block.

Authors:  Giovana Radomille Tófoli; Juliana Cama Ramacciato; Patrícia Cristine de Oliveira; Maria Cristina Volpato; Francisco Carlos Groppo; José Ranali
Journal:  Anesth Prog       Date:  2003

7.  Change in dental pulp parameters in response to different modes of orthodontic force application.

Authors:  Rita Veberiene; Dalia Smailiene; Nomeda Baseviciene; Adolfas Toleikis; Vita Machiulskiene
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

8.  Evaluation of electric pulp test thresholds and correct probe tip placement site in developing incisors: a clinical study in 1200 teeth.

Authors:  I Turedi; A T Ulusoy
Journal:  Eur Arch Paediatr Dent       Date:  2022-03-23

9.  Evaluation of threshold response and appropriate electrode placement site for electric pulp testing in fluorosed anterior teeth: An in vivo study.

Authors:  Harikumar Vemisetty; Amulya Vanapatla; Polavarapu Venkata Ravichandra; Surakanti Jayaprada Reddy; Rajani Punna; Srujana Chandragiri
Journal:  Dent Res J (Isfahan)       Date:  2016 May-Jun

10.  Relationship between the difference in electric pulp test values and the diagnostic type of pulpitis.

Authors:  Huachao Sui; Yangyang Lv; Mo Xiao; Liwen Zhou; Feng Qiao; Jinxin Zheng; Cuicui Sun; Jieni Fu; Yufan Chen; Yimeng Liu; Jie Zhou; Ligeng Wu
Journal:  BMC Oral Health       Date:  2021-07-10       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.