Recruitment data for nerve cuff electrodes: implications for design of implantable stimulators.

D R McNeal, L L Baker, J T Symons.   

Abstract

Recruitment characteristics of nerve cuff electrodes implanted in four cats for five months were measured. Monopolar, bipolar, and tripolar configurations were considered. Approximately twice the current was required to achieve a given response using the tripolar configuration as compared with monopolar stimulation. Bipolar stimulation also required more current than monopolar stimulation. Using the recruitment data, a number of strategies for modulating muscle tension were considered. It was shown that both pulse amplitude and pulse duration should be software-selectable to achieve adequate control of muscle tension when using either pulse amplitude modulation or pulse duration modulation. When using pulse amplitude modulation, it was found to be desirable to operate at a low pulse duration in the high end of the allowable range for pulse amplitude. For pulse duration modulation, one should operate at a low pulse amplitude in the high end of the allowable range for pulse duration. The effect of pulse amplitude and pulse duration step size on the maximum step change in muscle tension and the linearity of the recruitment curves were examined. The use of logarithmic steps in the modulation parameter was examined and was shown to result in improved controllability and linearity.

Entities:  

Mesh:

Year:  1989        PMID: 2921067     DOI: 10.1109/10.19851

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Force-current relationships in intraneural stimulation: role of extraneural medium and motor fibre clustering.

Authors:  T A Frieswijk; J P Smit; W L Rutten; H B Boom
Journal:  Med Biol Eng Comput       Date:  1998-07       Impact factor: 2.602

2.  Modified implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width profiles.

Authors:  T O'Halloran; M Haugland; G M Lyons; T Sinkjaer
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

3.  Properties of implanted electrodes for functional electrical stimulation.

Authors:  D Popovic; T Gordon; V F Rafuse; A Prochazka
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

Review 4.  Tutorial: a computational framework for the design and optimization of peripheral neural interfaces.

Authors:  Simone Romeni; Giacomo Valle; Alberto Mazzoni; Silvestro Micera
Journal:  Nat Protoc       Date:  2020-09-28       Impact factor: 13.491

Review 5.  On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion.

Authors:  Max Ortiz-Catalan; Rickard Brånemark; Bo Håkansson; Jean Delbeke
Journal:  Biomed Eng Online       Date:  2012-06-20       Impact factor: 2.819

6.  Effect on signal-to-noise ratio of splitting the continuous contacts of cuff electrodes into smaller recording areas.

Authors:  Max Ortiz-Catalan; Jorge Marin-Millan; Jean Delbeke; Bo Håkansson; Rickard Brånemark
Journal:  J Neuroeng Rehabil       Date:  2013-02-21       Impact factor: 4.262

7.  An improved method of crafting a multi-electrode spiral cuff for the selective.

Authors:  Janez Rozman; Polona Pečlin; Samo Ribarič; Matjaž Godec; Jaka Burja
Journal:  Sci Rep       Date:  2018-01-17       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.