Literature DB >> 29210591

Duplicate Type and Screen Testing: Waste in the Clinical Laboratory.

Margaret L Compton, Penny C Szklarski, Garrett S Booth1.   

Abstract

CONTEXT: - In the United States, approximately $65 billion dollars is spent per year on clinical laboratory testing, of which 20% to 30% of all testing is deemed inappropriate. There have been multiple studies in the field of transfusion medicine regarding evidence-based transfusion practices, but limited data exist regarding inappropriate pretransfusion testing and its financial and clinical implications.
OBJECTIVE: - To assess duplicative testing practices in the transfusion medicine service.
DESIGN: - A 24-month retrospective review was performed at a 1025-bed tertiary care center, identifying all duplicate type and screen (TS) tests performed within 72 hours of the previous TS. Duplicative testing was classified as appropriate or inappropriate by predetermined criteria. The level of underordering was analyzed through a query of the electronic event reporting system. A cost analysis was performed to determine the financial impact of inappropriate duplicative TS.
RESULTS: - The mean rate of inappropriate, duplicative TS orders was 4.13% (standard deviation ± 4.09%). Rates of inappropriate ordering ranged from 0.01% to 15.5% depending on the clinical service and did not correlate with volume of tests ordered. There were 8 reported cases of delayed blood delivery due to lack of a valid TS during the study period, demonstrating that underordering is also a harmful practice. The laboratory cost of inappropriate testing for the study period was $80,434, and phlebotomy costs were $45,469.
CONCLUSIONS: - Our study demonstrates that inappropriate TS ordering is costly, both financially and clinically. By evaluating the percentage of inappropriate TS tests by clinical services, we have identified services that may benefit from additional education and technologic intervention.

Mesh:

Year:  2017        PMID: 29210591     DOI: 10.5858/arpa.2016-0629-OA

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  3 in total

1.  New EHR certification requirements and their association with duplicate tests and images.

Authors:  Yuriy Pylypchuk; Christian Johnson
Journal:  J Am Med Inform Assoc       Date:  2022-07-12       Impact factor: 7.942

2.  Incidence and Risk Factors for Inappropriate Use of Non-Culture-Based Fungal Assays: Implication for Diagnostic Stewardship.

Authors:  Hiroshi Ito; Koh Okamoto; Shinya Yamamoto; Marie Yamashita; Yoshiaki Kanno; Daisuke Jubishi; Mahoko Ikeda; Sohei Harada; Shu Okugawa; Kyoji Moriya
Journal:  Open Forum Infect Dis       Date:  2021-12-06       Impact factor: 3.835

3.  Enhancing the utilization of packed red blood cells stock in maternity hospitals.

Authors:  Waleed M Bawazir; Fahad M Dakkam
Journal:  Saudi Med J       Date:  2020-06       Impact factor: 1.484

  3 in total