Literature DB >> 29210176

Online measurement of hemodialysis adequacy using effective ionic dialysance of sodium-a review of its principles, applications, benefits, and risks.

Shakil Aslam1, Subodh J Saggi2, Moro Salifu2, Robert J Kossmann1.   

Abstract

Dialysis dose is an important determinant of clinical outcomes in patients with end stage renal disease on maintenance dialysis. In clinical practice dialysis dose is monitored at least monthly by urea clearance based on Urea Kinetic Modeling. Online clearance monitoring using effective ionic dialysance (EID) of sodium (Na+ ) is available on some hemodialysis machines. This paper reviews the background, methodology, additional applications, and potential risks associated with EID. Effective ionic dialysance provides a reliable, real-time, noninvasive, and inexpensive measurement of dialysis dose during an ongoing hemodialysis (HD) session to allow interventions and assess the impact of these changes on clearance. Surveillance of vascular access flow rates can be used to screen for access dysfunction and refer for interventions. There is a concern that EID measurements may cause Na+ loading because of high dialysate Na+ used during these measurements, however, mathematical models, in vitro experiments, and clinical studies in patients on maintenance HD do not show any evidence of Na+ loading during EID measurements. We cannot rule out the possibility of nonosmotic Na+ accumulation in the skin because no published literature exists on this topic as it pertains to clearance measurements based on EID of Na+ .
© 2017 The Authors Hemodialysis International published by Wiley Periodicals, Inc. on behalf of International Society for Hemodialysis.

Entities:  

Keywords:  Adequacy of dialysis; EID; Kecn; effective ionic dialyance; salt loading

Mesh:

Substances:

Year:  2017        PMID: 29210176     DOI: 10.1111/hdi.12623

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  4 in total

1.  What volume to choose to assess online Kt/V?

Authors:  Francesco Gaetano Casino; Elena Mancini; Giovanni Santarsia; Salvatore Domenico Mostacci; Filomena D'Elia; Maria Di Carlo; Francesco Iannuzzella; Luigi Rossi; Luigi Vernaglione; Daniela Grimaldi; Renato Rapanà; Carlo Basile
Journal:  J Nephrol       Date:  2019-08-07       Impact factor: 3.902

2.  A novel method to rapidly calculate the urea clearance index and urea reduction rate based on parameters obtained during hemodialysis.

Authors:  Yue Yang; Jia Chen; Wei Wang; Yu-Mei Zhang; Wen-Ge Li
Journal:  Chronic Dis Transl Med       Date:  2020-12-14

3.  Ensuring hemodialysis adequacy by dialysis dose monitoring with UV spectroscopy analysis of spent dialyzate.

Authors:  Li Zhang; Wenhu Liu; Chuanming Hao; Yani He; Ye Tao; Shiren Sun; Marten Jakob; Daniele Marcelli; Claudia Barth; Xiangmei Chen
Journal:  Int J Artif Organs       Date:  2021-11-23       Impact factor: 1.595

4.  Using the Intelligent System to Improve the Delivered Adequacy of Dialysis by Preventing Intradialytic Complications.

Authors:  Mohammad Karimi; Daryoosh Dideban; Hadi Heidari
Journal:  J Healthc Eng       Date:  2022-06-23       Impact factor: 3.822

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.