| Literature DB >> 29207866 |
Eonju Lee1, Won Park1, Sung Hwan Ahn1, Jae Ho Cho2, Jin Hee Kim3, Kwan Ho Cho4, Young Min Choi5, Jae-Sung Kim6, Jin Ho Kim7, Hong-Seok Jang8, Young-Seok Kim9, Taek-Keun Nam10.
Abstract
PURPOSE: To investigate interobserver variation in target volume delineations for prostate cancer salvage radiotherapy using planning computed tomography (CT) versus combined planning CT and magnetic resonance imaging (MRI).Entities:
Keywords: Interobserver variation; Magnetic resonance image; Prostate cancer; Salvage radiotherapy; Target volume
Year: 2017 PMID: 29207866 PMCID: PMC5903365 DOI: 10.3857/roj.2017.00080
Source DB: PubMed Journal: Radiat Oncol J ISSN: 2234-1900
Case characteristics
| Case | Initial PSA (ng/mL) | Gleason score | Pathologic stage[ | Positive margins | bDFS (mo) | preRT PSA (ng/mL) |
|---|---|---|---|---|---|---|
| 1 | 3.47 | 7 | pT2cN0 | No | 23 | 0.33 |
| 2 | 3.36 | 6 | pT2cN0 | No | 28 | 0.22 |
| 3 | 3.12 | 7 | pT3aN0 | No | 77 | 0.50 |
| 4 | 5.71 | 7 | pT3aN0 | No | 6 | 0.24 |
| 5 | 10.24 | 8 | pT3bN0 | Right base | 40 | 0.31 |
PSA, prostate-specific antigen; bDFS, biochemical disease-free survival; RT, radiotherapy.
AJCC Cancer Staging Manual, 7th edition.
Institutions’ radiotherapy practice
| Institution | No. of salvage treatment cases at 2012 | MRI fusion for planning | Endorectal ballooning | Bladder filling |
|---|---|---|---|---|
| 1 | 73 | Yes | Yes | No |
| 2 | 58 | No | No | No |
| 3 | 57 | No | Yes | No |
| 4 | 49 | No | Yes | Yes |
| 5 | 44 | Yes | Yes | Yes |
| 6 | 23 | No | No | Yes |
| 7 | 21 | Yes | Yes | Yes |
| 8 | 20 | No | No | No |
| 9 | 6 | No | Yes | Yes |
| 10 | 5 | No | No | No |
MRI, magnetic resonance image.
Interobserver variations of CTV according to acquired planning images
| CTV1 (cm3) | CTV2 (cm3) | |
|---|---|---|
| Case 1 | 44.54 (9.44–92.10) | 45.34 (10.6–83.4) |
| Case 2 | 42.91 (12.87–83.92) | 41.56 (8.75–81.54) |
| Case 3 | 60.68 (12.39–139.27) | 58.74 (13.96–122.83) |
| Case 4 | 54.98 (9.97–106.16) | 54.61 (7.77–119.69) |
| Case 5 | 49.73 (11.89–94.35) | 48.04 (11.71–84.66) |
Values are presented as mean (range).
CTV, clinical target volume; CTV1, delineated by planning computed tomography only; CTV2, delineated by planning computed tomography fusion with magnetic resonance image.
Fig. 1.(A) Mean volume with standard error and (B) percentage decrease of clinical target volume (CTV) in each case. CTV1, delineated by planning computed tomography only; CTV2, delineated by planning computed tomography fusion with magnetic resonance image.
Fig. 2.Mean volume with standard error of all 5 cases in each observer. CTV, clinical target volume; CTV1, delineated by planning computed tomography only; CTV2, delineated by planning computed tomography fusion with magnetic resonance image.