Literature DB >> 2920743

Automatic assignment of elliptical ROIs: first results in planar scintigrams of the left ventricle.

J A Blokland1, A M Vossepoel, A R Bakker, E K Pauwels.   

Abstract

Several algorithms for quantitative analysis of 201Tl scintigrams require operator assigned elliptical regions. Therefore these algorithms are hampered by inter- and intra-observer errors. In this paper we present a robust algorithm to determine automatically contours with elliptical shapes. The algorithm is based on the Hough transformation and can determine the parameters describing an ellipse even in low signal-to-noise ratio images and when the contour is only partially visualized such as in non-perfused regions of the left ventricular myocardium. As long as the number of parameters to describe the shape of the contour is not too large, the same kind of algorithm can also be used for differently shaped contours, and for 3D elliptical contours as in SPECT.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2920743     DOI: 10.1007/BF00702625

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  5 in total

1.  Delineating elliptical objects with an application to cardiac scintigrams.

Authors:  J A Blokland; A M Vossepoel; A R Bakker; E K Pauwels
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

2.  "Circumferential profiles:" a new method for computer analysis of thallium-201 myocardial perfusion images.

Authors:  R D Burow; M Pond; A W Schafer; L Becker
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

3.  A new approach to quantitation of exercise thallium-201 scintigraphy before and after an intervention: application to define the impact of coronary angioplasty on regional myocardial perfusion.

Authors:  Y L Lim; R D Okada; D A Chesler; P C Block; C A Boucher; G M Pohost
Journal:  Am Heart J       Date:  1984-10       Impact factor: 4.749

4.  Improved noninvasive assessment of coronary artery disease by quantitative analysis of regional stress myocardial distribution and washout of thallium-201.

Authors:  J Maddahi; E V Garcia; D S Berman; A Waxman; H J Swan; J Forrester
Journal:  Circulation       Date:  1981-11       Impact factor: 29.690

5.  Sensitivity and specificity of thallium-201 perfusion scintigrams under exercise in the diagnosis of coronary artery disease.

Authors:  M S Verani; M L Marcus; M A Razzak; J C Ehrhardt
Journal:  J Nucl Med       Date:  1978-07       Impact factor: 10.057

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.