Literature DB >> 29206569

Application of Miniature Heart Rate Data Loggers for Use in Large Free-Moving Decapod Crustaceans: Method Development and Validation.

Iain J McGaw, S Clay Steell, Travis E Van Leeuwen, Erika J Eliason, Steven J Cooke.   

Abstract

Cardiovascular responses of decapod crustaceans to environmental challenges have received extensive attention. However, nearly all of these studies have been restricted to lab-based experiments; here we describe a methodology that will enable measurement of heart rate (HR) in free-moving decapods in the field. Data storage tag heart rate and temperature loggers (DST micro-HRT; Star-Oddi) were used to record electrocardiograms (ECG) and HR in large decapod crustaceans. These loggers were originally designed for use in vertebrates and must be surgically implanted in the body cavity near the heart in order to function. We adapted these loggers for external use in large decapod crustaceans. The method involved abrading the carapace directly above the heart and placing the electrodes of the logger directly on top of the dermal tissue. The logger was then secured in place with periphery wax. This method negated some of the more intricate operations used for vertebrates. The rapid setup time of approximately 5 min suggested that animals could be easily instrumented in the field and without the use of anesthetic. The logger was calibrated by simultaneously measuring the HR changes of a West Indian spider crab Mithrax spinosissimus with a pulsed-Doppler flowmeter. The data gathered with the two methods showed a tight correlation during an increase in temperature. The loggers were also successfully implanted in a variety of other large species of aquatic and terrestrial decapods. The data obtained showed that the method works in a broad range of species, under different experimental conditions. In each case, the loggers comprised less than 1% of the body mass and would be suitable for use in animals >300 g. All animals survived the attachment procedures and were feeding and active after removal of the loggers. Nearly all previous cardiac measurements on decapods have been carried out in controlled laboratory settings. The use of these loggers will make significant advances in measuring HR in unrestrained, undisturbed animals in their natural environment during extended periods of time and has the potential to lead to novel findings.

Entities:  

Keywords:  Star-Oddi; crustacean; data logger; heart rate; physiology

Mesh:

Year:  2018        PMID: 29206569     DOI: 10.1086/695839

Source DB:  PubMed          Journal:  Physiol Biochem Zool        ISSN: 1522-2152            Impact factor:   2.247


  3 in total

Review 1.  Bio-sensing technologies in aquaculture: how remote monitoring can bring us closer to our farm animals.

Authors:  J Brijs; M Føre; A Gräns; T D Clark; M Axelsson; J L Johansen
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2021-06-14       Impact factor: 6.671

2.  Non-invasive MRI Studies of Ventilatory and Cardiovascular Performance in Edible Crabs Cancer pagurus During Warming Under Elevated CO2 Levels.

Authors:  Bastian Maus; Sebastian Gutsfeld; Christian Bock; Hans-Otto Pörtner
Journal:  Front Physiol       Date:  2021-01-11       Impact factor: 4.566

3.  Caprellid amphipods (Caprella spp.) are vulnerable to both physiological and habitat-mediated effects of ocean acidification.

Authors:  Emily G Lim; Christopher D G Harley
Journal:  PeerJ       Date:  2018-07-31       Impact factor: 2.984

  3 in total