Literature DB >> 29203949

Simultaneous Wireless Power Transfer and Data Communication Using Synchronous Pulse-Controlled Load Modulation.

Shitong Mao1,2,3, Hao Wang1,2, Chunbo Zhu3, Zhi-Hong Mao2, Mingui Sun1,2.   

Abstract

Wireless Power Transfer (WPT) and wireless data communication are both important problems of research with various applications, especially in medicine. However, these two problems are usually studied separately. In this work, we present a joint study of both problems. Most medical electronic devices, such as smart implants, must have both a power supply to allow continuous operation and a communication link to pass information. Traditionally, separate wireless channels for power transfer and communication are utilized, which complicate the system structure, increase power consumption and make device miniaturization difficult. A more effective approach is to use a single wireless link with both functions of delivering power and passing information. We present a design of such a wireless link in which power and data travel in opposite directions. In order to aggressively miniaturize the implant and reduce power consumption, we eliminate the traditional multi-bit Analog-to-Digital Converter (ADC), digital memory and data transmission circuits all together. Instead, we use a pulse stream, which is obtained from the original biological signal, by a sigma-delta converter and an edge detector, to alter the load properties of the WPT channel. The resulting WPT signal is synchronized with the load changes therefore requiring no memory elements to record inter-pulse intervals. We take advantage of the high sensitivity of the resonant WPT to the load change, and the system dynamic response is used to transfer each pulse. The transient time of the WPT system is analyzed using the coupling mode theory (CMT). Our experimental results show that the memoryless approach works well for both power delivery and data transmission, providing a new wireless platform for the design of future miniaturized medical implants.

Entities:  

Keywords:  Wireless power transfer; coupling mode theory; data communication; load modulation; transient process

Year:  2017        PMID: 29203949      PMCID: PMC5710816          DOI: 10.1016/j.measurement.2017.05.068

Source DB:  PubMed          Journal:  Measurement (Lond)        ISSN: 0263-2241            Impact factor:   3.927


  15 in total

Review 1.  Event-related EEG/MEG synchronization and desynchronization: basic principles.

Authors:  G Pfurtscheller; F H Lopes da Silva
Journal:  Clin Neurophysiol       Date:  1999-11       Impact factor: 3.708

2.  The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission.

Authors:  Mehdi Kiani; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst I Regul Pap       Date:  2012-09       Impact factor: 3.605

3.  Wireless power transfer via strongly coupled magnetic resonances.

Authors:  André Kurs; Aristeidis Karalis; Robert Moffatt; J D Joannopoulos; Peter Fisher; Marin Soljacic
Journal:  Science       Date:  2007-06-07       Impact factor: 47.728

4.  Power-efficient impedance-modulation wireless data links for biomedical implants.

Authors:  S Mandal; R Sarpeshkar
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2008-12       Impact factor: 3.833

5.  High-Speed OQPSK and Efficient Power Transfer Through Inductive Link for Biomedical Implants.

Authors:  Guillaume Simard; Mohamad Sawan; Daniel Massicotte
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2010-06       Impact factor: 3.833

6.  A spectral analysis of the normal resting electrocardiogram.

Authors:  D P Golden; R A Wolthuis; G W Hoffler
Journal:  IEEE Trans Biomed Eng       Date:  1973-09       Impact factor: 4.538

7.  A Fully Implantable Stimulator With Wireless Power and Data Transmission for Experimental Investigation of Epidural Spinal Cord Stimulation.

Authors:  Qi Xu; Dingyin Hu; Bingyu Duan; Jiping He
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2015-02-10       Impact factor: 3.802

8.  An implantable, batteryless, and wireless capsule with integrated impedance and pH sensors for gastroesophageal reflux monitoring.

Authors:  Hung Cao; Vaibhav Landge; Uday Tata; Young-Sik Seo; Smitha Rao; Shou-Jiang Tang; H F Tibbals; Stuart Spechler; J-C Chiao
Journal:  IEEE Trans Biomed Eng       Date:  2012-08-22       Impact factor: 4.538

Review 9.  Power Approaches for Implantable Medical Devices.

Authors:  Achraf Ben Amar; Ammar B Kouki; Hung Cao
Journal:  Sensors (Basel)       Date:  2015-11-13       Impact factor: 3.576

Review 10.  Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review.

Authors:  Kara N Bocan; Ervin Sejdić
Journal:  Sensors (Basel)       Date:  2016-03-18       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.