Literature DB >> 29202438

Spatial-resolved dual-signal-output electrochemiluminescent ratiometric strategy for accurate and sensitive immunoassay.

Yu-Ling Wang1, Fu-Rao Liu1, Jun-Tao Cao2, Shu-Wei Ren3, Yan-Ming Liu4.   

Abstract

The identification of tumor markers is of great importance for clinical diagnosis but accurate detection with high sensitivity is still a great challenge. In present work, a spatial-resolved dual-signal-output electrochemiluminescent (ECL) ratiometric assay platform was constructed for sensitive detection of prostate specific antigen (PSA) on a dual-disk glassy carbon electrode. To fabricate the platform, flower-like CdS three-dimensional (3D) assemblies and Ru(bpy)32+-conjugated silica nanoparticles (Ru(bpy)32+@RuSi NPs), were immobilized onto the two disks as cathodic and anodic ECL emitters, respectively. After the stepwise modification of the gold nanoparticles, antibody for PSA, and bovine serum albumin onto the two disks respectively, the Ru(bpy)32+@RuSi NPs-based disk were incubated with varied concentration of PSA as working electrode, whereas the flower-like CdS 3D assemblies-based disk with fixed concentration of PSA were taken as internal reference electrode. The label free assay of PSA was realized by the ratio of anodic ECL signal from working electrode to the cathodic ECL signal from the internal reference electrode (ECLanode/ECLcathode). On the basis of the spatial-resolved dual-signal-output ratiometric ECL sensor, the PSA can be detected accurately with a linear range of 0.001 - 50ng/mL at a concentration as low as 0.34pg/mL. Furthermore, the proposed method was applied for PSA determination in human serum samples with satisfying results. Thanks to the same modified process of the two disks, this universal design well avoids environmental errors including the interference caused in the biological recognition process, which effectively reduces the false positive or negative errors, exhibiting a greatly improved accuracy, reliability and sensitivity.
Copyright © 2017. Published by Elsevier B.V.

Entities:  

Keywords:  Accurate detection with high sensitivity; Dual-signal-output ratiometry; Prostate specific antigen; Spatial-resolved technology; Two different signal-tags

Mesh:

Substances:

Year:  2017        PMID: 29202438     DOI: 10.1016/j.bios.2017.11.067

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  A redox-mediator pathway for enhanced multi-colour electrochemiluminescence in aqueous solution.

Authors:  Emily Kerr; David J Hayne; Lachlan C Soulsby; Joseph C Bawden; Steven J Blom; Egan H Doeven; Luke C Henderson; Conor F Hogan; Paul S Francis
Journal:  Chem Sci       Date:  2021-12-15       Impact factor: 9.825

Review 2.  Recent advances and future prospects of the potential-resolved strategy in ratiometric, multiplex, and multicolor electrochemiluminescence analysis.

Authors:  Shijun Wang; Shu Zhu; Ziqi Kang; Yidan Chen; Xiancheng Liu; Zixin Deng; Kun Hu; Guixue Wang; Yuchan Zhang; Guangchao Zang
Journal:  Theranostics       Date:  2022-09-21       Impact factor: 11.600

Review 3.  Emerging nanobiotechnology for precise theranostics of hepatocellular carcinoma.

Authors:  Mengjiao Xu; Liu Yang; Yanjie Lin; Yao Lu; Xiaoyue Bi; Tingting Jiang; Wen Deng; Lu Zhang; Wei Yi; Yao Xie; Minghui Li
Journal:  J Nanobiotechnology       Date:  2022-09-29       Impact factor: 9.429

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.