Literature DB >> 29202303

SPR imaging biosensor for the quantitation of fibronectin concentration in blood samples.

Anna Sankiewicz1, Lech Romanowicz2, Marlena Pyc3, Adam Hermanowicz4, Ewa Gorodkiewicz5.   

Abstract

The purpose of this study was presentation of a new biosensor capable of determination of fibronectin. This biosensor was based on the specific interaction of anti-fibronectin antibody produced in rabbit with fibronectin. The surface plasmon resonance imaging (SPRI) technique was used as a detecting method. Optimization and characterization properties of the biosensor were studied. The determination of fibronectin concentration in natural samples was done. The results were compared with a reference method (Enzyme-Linked Immunosorbent Assay-ELISA). The analytically useful dynamic response range of biosensor is between 5 and 400ngmL-1. The detection limit is 1.5ngmL-1 and limit quantification is 5ngmL-1. The proposed SPRI biosensor showed good selectivity for potential interferences. It was applied to determine fibronectin concentrations in plasma of healthy donors and of patients after thermal injury. Good correlations between results obtained using the SPRI biosensor and ELISA test (correlation coefficients for healthy donors 0.996, for patients 0.984) were obtained. The average fibronectin concentration of healthy donors was 140.5±24.6μgmL -1 and the average fibronectin concentration of patients was 601.5±72.1μgmL -1, which was in agreement with results obtained by other investigators. The obtained results indicate that the developed biosensor may be a candidate for monitoring fibronectin concentration in blood samples.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Fibronectin; Surface plasmon resonance imaging

Mesh:

Substances:

Year:  2017        PMID: 29202303     DOI: 10.1016/j.jpba.2017.11.070

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  8 in total

1.  Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi.

Authors:  Beata Szymanska; Zenon Lukaszewski; Lukasz Oldak; Beata Zelazowska-Rutkowska; Kinga Hermanowicz-Szamatowicz; Ewa Gorodkiewicz
Journal:  Biosensors (Basel)       Date:  2022-06-14

2.  Levels of Selected Matrix Metalloproteinases-MMP-1, MMP-2 and Fibronectin in the Saliva of Patients Planned for Endodontic Treatment or Surgical Extraction.

Authors:  Ewa Matuszczak; Izabela Cwalina; Marzena Tylicka; Katarzyna Wawrzyn; Magdalena Nowosielska; Anna Sankiewicz; Łukasz Ołdak; Ewa Gorodkiewicz; Adam Hermanowicz
Journal:  J Clin Med       Date:  2020-12-07       Impact factor: 4.241

Review 3.  Electrochemically Deposited Molecularly Imprinted Polymer-Based Sensors.

Authors:  Simonas Ramanavičius; Inga Morkvėnaitė-Vilkončienė; Urtė Samukaitė-Bubnienė; Vilma Ratautaitė; Ieva Plikusienė; Roman Viter; Arūnas Ramanavičius
Journal:  Sensors (Basel)       Date:  2022-02-08       Impact factor: 3.576

Review 4.  Recent Advancements in Receptor Layer Engineering for Applications in SPR-Based Immunodiagnostics.

Authors:  Marcin Drozd; Sylwia Karoń; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-05-29       Impact factor: 3.576

Review 5.  Bioanalytical methods for circulating extracellular matrix-related proteins: new opportunities in cancer diagnosis.

Authors:  Ramón Lorenzo-Gómez; Rebeca Miranda-Castro; Noemí de-Los-Santos-Álvarez; María Jesús Lobo-Castañón
Journal:  Anal Bioanal Chem       Date:  2021-06-05       Impact factor: 4.142

Review 6.  Recent Progress in Optical Sensors for Biomedical Diagnostics.

Authors:  Muqsit Pirzada; Zeynep Altintas
Journal:  Micromachines (Basel)       Date:  2020-03-30       Impact factor: 2.891

7.  UCHL1 and Proteasome in Blood Serum in Relation to Dietary Habits, Concentration of Selected Antioxidant Minerals and Total Antioxidant Status among Patients with Alzheimer's Disease.

Authors:  Sylwia Bogdan; Anna Puścion-Jakubik; Katarzyna Klimiuk; Katarzyna Socha; Jan Kochanowicz; Ewa Gorodkiewicz
Journal:  J Clin Med       Date:  2022-01-14       Impact factor: 4.241

8.  An Immunosensor for the Determination of Cathepsin S in Blood Plasma by Array SPRi-A Comparison of Analytical Properties of Silver-Gold and Pure Gold Chips.

Authors:  Pawel Falkowski; Piotr Mrozek; Zenon Lukaszewski; Lukasz Oldak; Ewa Gorodkiewicz
Journal:  Biosensors (Basel)       Date:  2021-08-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.