| Literature DB >> 29196640 |
Pengfei Qi1, Lie Lin1, Rui Huang2, Sicong Zhao1, Haolin Tian1, Shuai Li1, Qinghe Zhang2, Weiwei Liu3.
Abstract
An image fiber-based miniature suspended solid sensor has been demonstrated. The diameter of the sensor is only a few millimeters. A superhydrophobic material is coated on the end of the image fiber to avoid the adsorption of suspended solids and bubbles. Multiple parameters, including mass concentration, morphology and particle sizes of suspended solids, can be visually measured in real time. Dynamic ranges of 0 ~100 kg/m3, full range accuracies of ±2‰ and a response time of 0.05 s were experimentally realized for the mass concentration measurements. Determinations of particle sizes of the suspended solids are also presented by means of digital image processing. This new technique will significantly advance ultralow-intrusion measurements in studies on the dynamics of suspended solids.Entities:
Year: 2017 PMID: 29196640 PMCID: PMC5711881 DOI: 10.1038/s41598-017-17003-y
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Schematic diagram of the measurement equipment setup.
Figure 2Experimental results and fit lines of the measurements over multiple ranges of SS mass concentrations; (a) extraction process of G(C ) from the captured images; (b) relationship between gray value ln(G-Gb) and mass concentration over multiple ranges of 0~20 kg/m3, 20~35 kg/m3, 35~50 kg/m3, 50~75 kg/m3 and 75~100 kg/m3; (c) residual errors of the local linear and global curve fits corresponding to (b).
Local linear fitting parameters and global curve fitting function corresponding to Fig. 2(b).
| Range (kg/m3) | Offset | Intercept | Slope | R-Square |
|---|---|---|---|---|
| 0~20 | 0 | 6.30974 | −0.16591 | 0.99956 |
| 20~35 | −2.51114 | 5.81635 | −0.14276 | 0.99979 |
| 35~50 | −5.05631 | 4.85627 | −0.11566 | 0.99937 |
| 50~75 | −7.11119 | 2.86963 | −0.07627 | 0.99994 |
| 75~100 | −8.62731 | 2.09986 | −0.06602 | 0.99956 |
| 0~100 | ln( | 0.99943 | ||
Figure 3Influence of particle size on measurement of SS, (a) experimental results (scattered points) and fit lines (solid lines) of SS for different sieving center diameters, (b) extinction coefficients of unit concentrations of SS with different sieving center diameters (scattered points) and fitting curve (solid curve).
Figure 4The original and processed images of (a) the measuring equipment based on image fiber and (b) the microscope, the SiC with sieving mesh of 240 is taken as an example. The green and red solid curves show the profiles of the gray values along the corresponding dotted lines.
Figure 5Measurements (blue histograms) and lognormal fitting results (red solid lines) of particle size distributions using the equipment based on the image fiber and microscope.
Lognormal fitting parameters corresponding to Fig. 5.
| Parameters Mesh | Image fiber | Microscope | Error in | Conformity (Spearman Corr.) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
| |||
| 1000 | 0.012 | 18.594 | 0.086 | 1.650 | 0.010 | 17.195 | 0.124 | 1.565 | 8.14% | 0.97113 |
| 500 | 0.003 | 21.224 | 0.289 | 2.308 | 0.001 | 23.685 | 0.284 | 2.439 | 10.39% | 0.95646 |
| 320 | −0.001 | 47.959 | 0.508 | 10.282 | −0.005 | 43.911 | 0.496 | 11.252 | 9.22% | 0.9982 |
| 240 | −0.006 | 64.523 | 0.591 | 11.738 | −0.008 | 64.474 | 0.515 | 9.766 | 0.08% | 0.99528 |
| 180 | −0.002 | 89.418 | 0.477 | 10.805 | −0.010 | 86.715 | 0.462 | 10.607 | 3.12% | 0.99956 |
| 150 | −0.008 | 113.498 | 0.451 | 13.138 | −0.009 | 121.078 | 0.417 | 12.249 | 6.26% | 0.98324 |