Literature DB >> 29196090

Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis.

Apostolos Kiaos1, Ioannis Tziatzios1, Stavros Hadjimiltiades1, Charalambos Karvounis1, Theodoros D Karamitsos2.   

Abstract

INTRODUCTION: The purpose of this study was to investigate the accuracy of qualitative stress perfusion cardiac magnetic resonance (CMR) to diagnose ischemia-causing lesions according to different definitions of significant coronary artery disease (CAD), and magnetic field strength.
METHODS: We searched PubMed, Web of Science, and the Cochrane Library for studies evaluating diagnostic performance of qualitative stress perfusion CMR for diagnosis of CAD versus coronary angiography or fractional flow reserve (FFR) from inception to 10 September 2017. We used hierarchical models to synthesize the available data.
RESULTS: Sixty-seven studies (7113 patients) met the inclusion criteria. The patient-based analysis of studies using FFR as the reference standard demonstrated a mean sensitivity of 0.90 (95% confidence interval [CI], 0.85-0.93) and a mean specificity of 0.85 (95% CI, 0.80-0.89). The patient-based analyses for detecting coronary stenosis ≥50% and coronary stenosis ≥70% at 1.5T and for detecting coronary stenosis ≥50% and coronary stenosis ≥70%, at 3T, demonstrated a mean sensitivity of 0.82 (95% CI, 0.79-0.84), 0.86 (95% CI, 0.83-0.89), 0.90 (95% CI, 0.82-0.95), and 0.91 (95% CI, 0.79-0.96), respectively; with a mean specificity of 0.75 (95% CI, 0.71-0.80), 0.77 (95% CI, 0.71-0.81), 0.79 (95% CI, 0.69-0.86), and 0.74 (95% CI, 0.59-0.85).
CONCLUSION: Qualitative stress perfusion CMR has high accuracy for the diagnosis of CAD, irrespective of the reference standard and the magnet strength. Studies using FFR as the reference standard had higher diagnostic accuracy on a patient level compared to studies using coronary angiography, with a notable difference in specificity.
Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Cardiovascular magnetic resonance; Coronary artery disease; Diagnostic accuracy meta-analysis; Stress perfusion

Mesh:

Year:  2017        PMID: 29196090     DOI: 10.1016/j.ijcard.2017.11.066

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  7 in total

1.  Hybrid anatomo-functional imaging of coronary artery disease: Beneficial irrespective of its core components.

Authors:  Francesco Nudi; Giuseppe Biondi-Zoccai; Andrea Romagnoli; Orazio Schillaci; Alessandro Nudi; Francesco Versaci
Journal:  J Nucl Cardiol       Date:  2018-12-18       Impact factor: 5.952

2.  Impact of baseline calibration on semiquantitative assessment of myocardial perfusion reserve by adenosine stress MRI.

Authors:  Andreas Seitz; Giancarlo Pirozzolo; Udo Sechtem; Raffi Bekeredjian; Peter Ong; Heiko Mahrholdt
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-14       Impact factor: 2.357

3.  Impact of caffeine on myocardial perfusion reserve assessed by semiquantitative adenosine stress perfusion cardiovascular magnetic resonance.

Authors:  Andreas Seitz; Philipp Kaesemann; Maria Chatzitofi; Stephanie Löbig; Gloria Tauscher; Raffi Bekeredjian; Udo Sechtem; Heiko Mahrholdt; Simon Greulich
Journal:  J Cardiovasc Magn Reson       Date:  2019-06-24       Impact factor: 5.364

Review 4.  Stress CMR in Known or Suspected CAD: Diagnostic and Prognostic Role.

Authors:  Francesca Baessato; Marco Guglielmo; Giuseppe Muscogiuri; Andrea Baggiano; Laura Fusini; Stefano Scafuri; Mario Babbaro; Rocco Mollace; Ada Collevecchio; Andrea I Guaricci; Gianluca Pontone
Journal:  Biomed Res Int       Date:  2021-01-14       Impact factor: 3.411

Review 5.  Clinical Application of Dynamic Contrast Enhanced Perfusion Imaging by Cardiovascular Magnetic Resonance.

Authors:  Russell Franks; Sven Plein; Amedeo Chiribiri
Journal:  Front Cardiovasc Med       Date:  2021-10-29

6.  Stress Perfusion Cardiac Magnetic Resonance Imaging With a 3.0-Tesla Scanner for Myocardial Viability in a Patient With a Conditional Pacemaker.

Authors:  Pouya Motazedian; Graeme Prosperi-Porta; Mobeen Ahmed; Moiz Hafeez; Naeem Merchant; Bobak Heydari
Journal:  CJC Open       Date:  2022-03-03

7.  Data on diagnostic performance of stress perfusion cardiac magnetic resonance for coronary artery disease detection at the vessel level.

Authors:  Apostolos Kiaos; Ioannis Tziatzios; Stavros Hadjimiltiades; Charalambos Karvounis; Theodoros D Karamitsos
Journal:  Data Brief       Date:  2017-12-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.