Literature DB >> 29195351

OMNY PIN-A versatile sample holder for tomographic measurements at room and cryogenic temperatures.

M Holler1, J Raabe1, R Wepf2, S H Shahmoradian1, A Diaz1, B Sarafimov1, T Lachat3, H Walther1, M Vitins1.   

Abstract

Nowadays ptychographic tomography in the hard x-ray regime, i.e., at energies above about 2 keV, is a well-established measurement technique. At the Paul Scherrer Institut, currently two instruments are available: one is measuring at room temperature and atmospheric pressure, and the other, the so-called OMNY (tOMography Nano crYo) instrument, is operating at ultra-high vacuum and offering cryogenic sample temperatures down to 10 K. In this manuscript, we present the sample mounts that were developed for these instruments. Aside from excellent mechanical stability and thermal conductivity, they also offer highly reproducible mounting. Various types were developed for different kinds of samples and are presented in detail, including examples of how specimens can be mounted on these holders. We also show the first hard x-ray ptychographic tomography measurements of high-pressure frozen biological samples, in the present case Chlamydomonas cells, the related sample pins and preparation steps. For completeness, we present accessories such as transportation containers for both room temperature and cryogenic samples and a gripper mechanism for automatic sample changing. The sample mounts are not limited to x-ray tomography or hard x-ray energies, and we believe that they can be very useful for other instrumentation projects.

Year:  2017        PMID: 29195351     DOI: 10.1063/1.4996092

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  10 in total

1.  First ptychographic X-ray computed tomography experiment on the NanoMAX beamline.

Authors:  Maik Kahnt; Simone Sala; Ulf Johansson; Alexander Björling; Zhimin Jiang; Sebastian Kalbfleisch; Filip Lenrick; James H Pikul; Karina Thånell
Journal:  J Appl Crystallogr       Date:  2020-10-13       Impact factor: 3.304

2.  Dataset of ptychographic X-ray computed tomography of inverse opal photonic crystals produced by atomic layer deposition.

Authors:  Kaline P Furlan; Emanuel Larsson; Ana Diaz; Mirko Holler; Tobias Krekeler; Martin Ritter; Alexander Yu Petrov; Manfred Eich; Robert Blick; Gerold A Schneider; Imke Greving; Robert Zierold; Rolf Janßen
Journal:  Data Brief       Date:  2018-10-27

3.  Correlative Multiscale 3D Imaging of a Hierarchical Nanoporous Gold Catalyst by Electron, Ion and X-ray Nanotomography.

Authors:  Yakub Fam; Thomas L Sheppard; Ana Diaz; Torsten Scherer; Mirko Holler; Wu Wang; Di Wang; Patrice Brenner; Arne Wittstock; Jan-Dierk Grunwaldt
Journal:  ChemCatChem       Date:  2018-05-07       Impact factor: 5.686

4.  LamNI - an instrument for X-ray scanning microscopy in laminography geometry.

Authors:  Mirko Holler; Michal Odstrčil; Manuel Guizar-Sicairos; Maxime Lebugle; Ulrich Frommherz; Thierry Lachat; Oliver Bunk; Joerg Raabe; Gabriel Aeppli
Journal:  J Synchrotron Radiat       Date:  2020-04-06       Impact factor: 2.616

5.  Alterations in Sub-Axonal Architecture Between Normal Aging and Parkinson's Diseased Human Brains Using Label-Free Cryogenic X-ray Nanotomography.

Authors:  Hung Tri Tran; Esther H R Tsai; Amanda J Lewis; Tim Moors; J G J M Bol; Iman Rostami; Ana Diaz; Allert J Jonker; Manuel Guizar-Sicairos; Joerg Raabe; Henning Stahlberg; Wilma D J van de Berg; Mirko Holler; Sarah H Shahmoradian
Journal:  Front Neurosci       Date:  2020-11-25       Impact factor: 4.677

6.  Evolution of Hierarchically Porous Nickel Alumina Catalysts Studied by X-Ray Ptychography.

Authors:  Sebastian Weber; Ana Diaz; Mirko Holler; Andreas Schropp; Mikhail Lyubomirskiy; Ken L Abel; Maik Kahnt; Arno Jeromin; Satishkumar Kulkarni; Thomas F Keller; Roger Gläser; Thomas L Sheppard
Journal:  Adv Sci (Weinh)       Date:  2022-01-20       Impact factor: 16.806

7.  Environmental control for X-ray nanotomography.

Authors:  Mirko Holler; Tomas Aidukas; Lars Heller; Christian Appel; Nicholas W Phillips; Elisabeth Müller-Gubler; Manuel Guizar-Sicairos; Jörg Raabe; Johannes Ihli
Journal:  J Synchrotron Radiat       Date:  2022-07-21       Impact factor: 2.557

8.  X-ray Stain Localization with Near-Field Ptychographic Computed Tomography.

Authors:  Kirsten Taphorn; Madleen Busse; Johannes Brantl; Benedikt Günther; Ana Diaz; Mirko Holler; Martin Dierolf; Doris Mayr; Franz Pfeiffer; Julia Herzen
Journal:  Adv Sci (Weinh)       Date:  2022-06-24       Impact factor: 17.521

9.  A lathe system for micrometre-sized cylindrical sample preparation at room and cryogenic temperatures.

Authors:  Mirko Holler; Johannes Ihli; Esther H R Tsai; Fabio Nudelman; Mariana Verezhak; Wilma D J van de Berg; Sarah H Shahmoradian
Journal:  J Synchrotron Radiat       Date:  2020-01-29       Impact factor: 2.616

10.  Limited angle tomography for transmission X-ray microscopy using deep learning.

Authors:  Yixing Huang; Shengxiang Wang; Yong Guan; Andreas Maier
Journal:  J Synchrotron Radiat       Date:  2020-02-13       Impact factor: 2.616

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.