Robert Caiazzo 1,2 , Julien Branche 1,2 , Mehdi Daoudi 1,3 , Gilles Solecki 3 , Thomas Hubert 1 , Audrey Quenon 1 , Violeta Raverdy 1,2 , François Cousin 3 , François Henin 3 , Valery Dalle 3 , Stéphane Noel 3 , Geoffroy Vanbiervliet 4 , Marc Barthet 4 , François Pattou 1,2 . Show Affiliations »
Abstract
BACKGROUND AND STUDY AIMS : Endoscopic techniques have demonstrated their effectiveness in metabolic surgery, notably through a gastrointestinal (GI) liner, with a less invasive approach than conventional surgery. Our study evaluates the safety and efficacy of endoscopic GI anastomosis (EGIA) using a lumen-apposing stent to secure the anastomosis. MATERIALS AND METHODS : EGIA was performed using the transgastric approach with a two-channel endoscope with a novel stent (Cousin Biotech). First, a safety study with a follow-up of 12 months was performed on five piglets. Then, metabolic changes were investigated in a minipig model (n = 10) before and after EGIA or open GIA (OGIA). RESULTS: EGIA was technically successful with no complications observed during clinical monitoring. Endoscopic and postmortem examinations during the second part of study showed a secure anastomosis between the stomach and the intestinal limb in all except one minipig. Both minipigs subjected to EGIA and those in the control group (OGIA) exhibited increased postprandial glucagon-like peptide-1 (GLP-1) production (incretin secretion) and impaired D-xylose absorption (malabsorption effect). CONCLUSION : Performing EGIA with this dedicated stent appears safe, technically feasible, durable, and reproducible in providing a simple and effective endoscopic GI bypass capable of ensuring metabolic effect. © Georg Thieme Verlag KG Stuttgart · New York.
BACKGROUND AND STUDY AIMS : Endoscopic techniques have demonstrated their effectiveness in metabolic surgery, notably through a gastrointestinal (GI) liner, with a less invasive approach than conventional surgery. Our study evaluates the safety and efficacy of endoscopic GI anastomosis (EGIA) using a lumen-apposing stent to secure the anastomosis. MATERIALS AND METHODS : EGIA was performed using the transgastric approach with a two-channel endoscope with a novel stent (Cousin Biotech). First, a safety study with a follow-up of 12 months was performed on five piglets. Then, metabolic changes were investigated in a minipig model (n = 10) before and after EGIA or open GIA (OGIA). RESULTS: EGIA was technically successful with no complications observed during clinical monitoring. Endoscopic and postmortem examinations during the second part of study showed a secure anastomosis between the stomach and the intestinal limb in all except one minipig. Both minipigs subjected to EGIA and those in the control group (OGIA) exhibited increased postprandial glucagon-like peptide-1 (GLP-1 ) production (incretin secretion) and impaired D-xylose absorption (malabsorption effect). CONCLUSION : Performing EGIA with this dedicated stent appears safe, technically feasible, durable, and reproducible in providing a simple and effective endoscopic GI bypass capable of ensuring metabolic effect. © Georg Thieme Verlag KG Stuttgart · New York.
Entities: Chemical
Disease
Gene
Mesh: See more »
Substances: See more »
Year: 2017
PMID: 29195256 DOI: 10.1055/s-0043-120439
Source DB: PubMed Journal: Endoscopy ISSN: 0013-726X Impact factor: 10.093