Literature DB >> 29191609

Accuracy of various impression materials and methods for two implant systems: An effect size study.

Alexander Schmidt1, Teresa Häussling2, Peter Rehmann2, Heidrun Schaaf3, Bernd Wöstmann2.   

Abstract

PURPOSE: An accurate impression is required for implant treatment. The aim of this in-vitro study was to determine the effect size of the impression material/method, implant system and implant angulation on impression transfer precision.
METHODS: An upper jaw model with three BEGO and three Straumann implants (angulations 0°, 15°, 20°) in the left and right maxilla was used as a reference model. One polyether (Impregum Penta) and two polyvinyl siloxanes (Flexitime Monophase/Aquasil Ultra Monophase) were examined with two impression techniques (open and closed tray). A total of 60 impressions were made. A coordinate measurement machine was used to measure the target variables for 3D-shift, implant axis inclination and implant axis rotation. All the data were subjected to a four-way ANOVA. The effect size (partial eta-squared [η2P]) was reported.
RESULTS: The impression material had a significant influence on the 3D shift and the implant axis inclination deviation (p-values=.000), and both factors had very large effect sizes (3D-shift [η2P]=.599; implant axis inclination [η2P]=.298). Impressions made with polyvinyl siloxane exhibited the highest transfer precision. When the angulation of the implants was larger, more deviations occurred for the implant axis rotational deviation. The implant systems and impression methods showed partially significant variations (p-values=.001-.639) but only very small effect sizes (η2P=.001-.031).
CONCLUSIONS: The impression material had the greatest effect size on accuracy in terms of the 3D shift and the implant axis inclination. For multiunit restorations with disparallel implants, polyvinyl siloxane materials should be considered. In addition, the effect size of a multivariate investigation should be reported.
Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Effect size; Implant impression accuracy; Implant impression material; Implant impression method

Mesh:

Substances:

Year:  2017        PMID: 29191609     DOI: 10.1016/j.jpor.2017.10.004

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  5 in total

1.  A new 3D-method to assess the inter implant dimensions in patients - A pilot study.

Authors:  Alexander Schmidt; Jan-Wilhelm Billig; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  J Clin Exp Dent       Date:  2020-02-01

2.  Knowledge, Attitude, and Practice toward Impression Technique and Materials for Recording Impression in Implant Placement among Dental Practitioners in Patna City, Bihar.

Authors:  Ujjal Chatterjee; Ashish Srivastava; Abhinav Singh; Ankur Aggarwal; Chetan Jagdish; Akshat Sharma
Journal:  J Int Soc Prev Community Dent       Date:  2018-10-08

3.  Custom abutments on tilted implants in the maxilla: A clinical report.

Authors:  Fabrizio Di Francesco; Gennaro De Marco; Attilio Sommella; Alessandro Lanza
Journal:  Dent Res J (Isfahan)       Date:  2020-08-14

4.  3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions.

Authors:  Kuei-Ling Hsu; Abdulrahman A Balhaddad; Isadora Martini Garcia; Fabrício Mezzomo Collares; Vineet Dhar; Louis DePaola; Mary Anne Melo
Journal:  Saudi Dent J       Date:  2020-12-10

5.  A prospective clinical study on implant impression accuracy.

Authors:  Motaz Osman; Hassan Ziada; Ahmed Suliman; Neamat Hassan Abubakr
Journal:  Int J Implant Dent       Date:  2019-11-19
  5 in total