Literature DB >> 29189398

Quantification of the Effect of Shuttling on Computed Tomography Perfusion Parameters by Investigation of Aortic Inputs on Different Table Positions From Shuttle-Mode Scans of Lung and Liver Tumors.

Payel Ghosh, Adam G Chandler1, Brian P Hobbs2, Jia Sun2, John Rong3, David Hong4, Vivek Subbiah4, Filip Janku4, Aung Naing4, Wen-Jen Hwu5, Chaan S Ng.   

Abstract

OBJECTIVES: The aim of this study was to quantify the effect of shuttling on computed tomography perfusion (CTp) parameters derived from shuttle-mode body CT images using aortic inputs from different table positions.
METHODS: Axial shuttle-mode CT scans were acquired from 6 patients (10 phases, 2 nonoverlapping table positions 1.4 seconds apart) after contrast agent administration. Artifacts resulting from the shuttling motion were corrected with nonrigid registration before computing CTp maps from 4 aortic levels chosen from the most superior and inferior slices of each table position scan. The effect of shuttling on CTp parameters was estimated by mean differences in mappings obtained from aortic inputs in different table positions. Shuttling effect was also quantified using 95% limits of agreement of CTp parameter differences within-table and between-table aortic positions from the interaortic mean CTp values.
RESULTS: Blood flow, permeability surface, and hepatic arterial fraction differences were insignificant (P > 0.05) for both within-table and between-table comparisons. The 95% limits of agreement for within-table blood volume (BV) value deviations obtained from lung tumor regions were less than 4.7% (P = 0.18) compared with less than 12.2% (P = 0.003) for between-table BV value deviations. The 95% limits of agreement of within-table deviations for liver tumor regions were less than 1.9% (P = 0.55) for BV and less than 3.2% (P = 0.23) for mean transit time, whereas between-table BV and mean transit time deviations were less than 11.7% (P < 0.01) and less than 14.6% (P < 0.01), respectively. Values for normal liver tissue regions were concordant.
CONCLUSIONS: Computed tomography perfusion parameters acquired from aortic levels within-table positions generally yielded higher agreement than mappings obtained from aortic levels between-table positions indicating differences due to shuttling effect.

Entities:  

Mesh:

Year:  2018        PMID: 29189398      PMCID: PMC5951718          DOI: 10.1097/RCT.0000000000000686

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  13 in total

Review 1.  Brain imaging using multislice CT: a personal perspective.

Authors:  S F S Halpin
Journal:  Br J Radiol       Date:  2004       Impact factor: 3.039

Review 2.  Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, part 2: technical implementations.

Authors:  A A Konstas; G V Goldmakher; T-Y Lee; M H Lev
Journal:  AJNR Am J Neuroradiol       Date:  2009-03-19       Impact factor: 3.825

3.  Global image registration using a symmetric block-matching approach.

Authors:  Marc Modat; David M Cash; Pankaj Daga; Gavin P Winston; John S Duncan; Sébastien Ourselin
Journal:  J Med Imaging (Bellingham)       Date:  2014-09-19

4.  Adenosine-stress dynamic myocardial volume perfusion imaging with second generation dual-source computed tomography: Concepts and first experiences.

Authors:  Gorka Bastarrika; Luis Ramos-Duran; U Joseph Schoepf; Michael A Rosenblum; Joseph A Abro; Robin L Brothers; José L Zubieta; Salvatore A Chiaramida; Doo Kyoung Kang
Journal:  J Cardiovasc Comput Tomogr       Date:  2010-01-28

5.  Correction of Motion Artifacts From Shuttle Mode Computed Tomography Acquisitions for Body Perfusion Imaging Applications.

Authors:  Payel Ghosh; Adam G Chandler; Emre Altinmakas; John Rong; Chaan S Ng
Journal:  J Comput Assist Tomogr       Date:  2016 May-Jun       Impact factor: 1.826

6.  Effect on perfusion values of sampling interval of computed tomographic perfusion acquisitions in neuroendocrine liver metastases and normal liver.

Authors:  Chaan S Ng; Brian P Hobbs; Wei Wei; Ella F Anderson; Delise H Herron; James C Yao; Adam G Chandler
Journal:  J Comput Assist Tomogr       Date:  2015 May-Jun       Impact factor: 1.826

7.  Dynamic perfusion CT: optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients.

Authors:  Andreas Kämena; Florian Streitparth; Christian Grieser; Lukas Lehmkuhl; Basil Jamil; Katarzyna Wojtal; Jens Ricke; Maciej Pech
Journal:  Eur J Radiol       Date:  2007-03-23       Impact factor: 3.528

8.  Accuracy of dynamic computed tomography adenosine stress myocardial perfusion imaging in estimating myocardial blood flow at various degrees of coronary artery stenosis using a porcine animal model.

Authors:  Fabian Bamberg; Rabea Hinkel; Florian Schwarz; Torleif A Sandner; Elisabeth Baloch; Roy Marcus; Alexander Becker; Christian Kupatt; Bernd J Wintersperger; Thorsten R Johnson; Daniel Theisen; Ernst Klotz; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Invest Radiol       Date:  2012-01       Impact factor: 6.016

9.  Effect of sampling frequency on perfusion values in perfusion CT of lung tumors.

Authors:  Chaan S Ng; Adam G Chandler; Wei Wei; Ella F Anderson; Delise H Herron; Razelle Kurzrock; Chusilp Charnsangavej
Journal:  AJR Am J Roentgenol       Date:  2013-02       Impact factor: 3.959

10.  Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography.

Authors:  K A Miles; T-Y Lee; V Goh; E Klotz; C Cuenod; S Bisdas; A M Groves; M P Hayball; R Alonzi; T Brunner
Journal:  Eur Radiol       Date:  2012-02-26       Impact factor: 5.315