Abstract
BACKGROUND: The flexion relaxation phenomenon (FRP) has been widely investigated. Nevertheless, no study has been reported on the FRP as well as spasm response to large lifting load. The aim of this study was to evaluate the effect of large lifting load on the FRP response and spasm during execution of a flexion-extension exercise.Entities:
Keywords: Erector spinae; Lifting load; Low back pain; Muscular intensity; Trunk flexion-extension
Mesh:
Year: 2017 PMID: 29187168 PMCID: PMC5707781 DOI: 10.1186/s12891-017-1869-6
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Fig. 1a. A subject during flexion phase of a flexion–extension test in 15 kg lifting condition. b. The exemplar averaged bilateral EMG amplitude (MVC%) of a participant during flexion–extension performance with 0 kg hand load condition. The parallel vertical dotted lines represent EMG-off (left) and EMG-on (right) timing. TR = the time of relaxation period from EMG-off to EMG-on
Statistical results of Spasms and NEMG in relaxation period
| Lifting Load (kg) | Spasms | NEMG(%MVC) (Mean(SD)) | ||
|---|---|---|---|---|
| Case | prevalence | Absolute (%MVC) | Normalized | |
| 0 | 0 | 0 | 1.05(0.21) | 1.00(0.00) |
| 15 | 10a** | 45%a** | 1.87(0.33) a** | 1.78(0.09) a** |
| 20 | 15a**b* | 68%a**b* | 2.13(0.32) a** | 2.03(0.10) a**b* |
| 25 | 18a**b**c* | 82% a**b**c* | 2.37(0.40) a**b** | 2.26(0.12) a**b**c* |
** P < 0.01;*P < 0.05 (a = vs. 0 kg; b = vs. 15 kg; c = vs. 20 kg). (NEMG = mean normalized EMG)
Fig. 2Two samples (JW and HL) of bilateral EMG recordings from ES during flexion-extension performance with large lifting load condition, respectively. During relaxation period in 15 kg condition, subject JW shows some spasms in a form of low amplitude with sustained discharge mainly on left ES while HL having no spasms. In 20 kg condition, JW shows some spasms in form of sporadic potential discharge mainly on left ES while HL having a little spasm. In 25 kg, both JW and HL shows the spasms obviously triggered with sporadic large amplitude action potential discharge bilaterally. The vertical parallel dotted lines represent EMG-off (left red) and EMG-on (right red) timing