Literature DB >> 29186994

Supersonic shear imaging for the diagnosis of liver fibrosis and portal hypertension in liver diseases: a meta-analysis.

Han Deng1, Xingshun Qi2,3, Tiansong Zhang4, Xiaolong Qi3,5, Eric M Yoshida6, Xiaozhong Guo2.   

Abstract

BACKGROUND AND AIMS: The meta-analysis aimed to summarize the technical success rate of supersonic shear imaging (SSI) and to evaluate the diagnostic performance of liver and spleen stiffness measurement (LSM and SSM) with SSI for the detection of liver fibrosis, portal hypertension, and gastroesophageal varices in liver diseases.
METHODS: PubMed, EMBASE, and Cochrane Library databases were searched. Technical success rate of SSI was pooled. Area under curve (AUC), sensitivity, and specificity with corresponding 95% confidence interval (CI) were calculated.
RESULTS: Included studies regarding the diagnostic performance of SSI for liver fibrosis, portal hypertension, and esophageal varices numbered 28, 4, and 4 respectively. The pooled technical success rates of LSM and SSM were 95.3% and 75.5%, respectively. The AUC, sensitivity, and specificity of LSM/SSM for different stages of liver fibrosis were 0.85-0.94, 0.7-0.89, and 0.82-0.92, respectively. The AUC, sensitivity, and specificity of LSM were 0.84 (95%CI = 0.8-0.86), 0.79 (95%CI = 0.7-0.85), and 0.82 (95%CI = 0.72-0.88) for clinically significant portal hypertension, 0.85 (95%CI = 0.82-0.88), 0.8 (95%CI = 0.68-0.88), and 0.8 (95%CI = 0.6-0.92) for any varices, and 0.86 (95%CI = 0.83-0.89), 0.86 (95%CI = 0.76-0.92), and 0.61 (95%CI = 0.35-0.83) for high-risk varices, respectively.
CONCLUSIONS: LSM with SSI had a high diagnostic accuracy for liver fibrosis, but a moderate diagnostic accuracy for portal hypertension and esophageal varices.

Entities:  

Keywords:  Diagnostic accuracy; liver fibrosis; portal hypertension; stiffness measurement; varices

Mesh:

Year:  2017        PMID: 29186994     DOI: 10.1080/17474124.2018.1412257

Source DB:  PubMed          Journal:  Expert Rev Gastroenterol Hepatol        ISSN: 1747-4124            Impact factor:   3.869


  5 in total

1.  Performance of shear wave elastography: A single centre pilot study of mixed etiology liver disease patients with normal BMI.

Authors:  Shalini Thapar Laroia; Shyam Vellore Srinivasan; Komal Yadav; Archana Rastogi; Senthil Kumar; Guresh Kumar; Manoj Kumar
Journal:  Australas J Ultrasound Med       Date:  2021-05-09

2.  Spleen Transient Elastography and Damping Index Identify a Subgroup of Patients Without an Acute or Chronic Response to Beta-Blockers.

Authors:  Elba Llop; Christie Perelló; Teresa Fontanilla; Juan de la Revilla; Marta Hernández Conde; Marta López; Javier Minaya; Carlos Ferre; Javier Abad; Carlos Fernández Carrillo; José Luís Martínez; Natalia Fernández Puga; María Trapero; Ismael El Hajra; Elena Santos; José Luis Calleja
Journal:  Front Med (Lausanne)       Date:  2022-06-22

3.  Spleen Stiffness for Predicting Varices Needing Treatment: Comparison between Two Different Elastography Techniques (Point vs. 2D-SWE).

Authors:  Renata Fofiu; Felix Bende; Raluca Lupuşoru; Alina Popescu; Ioan Sporea
Journal:  Can J Gastroenterol Hepatol       Date:  2021-03-28

4.  Tumor elastography and its association with cell-free tumor DNA in the plasma of breast tumor patients: a pilot study.

Authors:  Yi Hao; Wei Yang; Wenyi Zheng; Xiaona Chen; Hui Wang; Liang Zhao; Jinfeng Xu; Xia Guo
Journal:  Quant Imaging Med Surg       Date:  2021-08

Review 5.  Role of two-dimensional shear wave elastography in chronic liver diseases: A narrative review.

Authors:  Jae Yoon Jeong; Young Seo Cho; Joo Hyun Sohn
Journal:  World J Gastroenterol       Date:  2018-09-14       Impact factor: 5.742

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.