PET attenuation correction for flexible MRI surface coils in hybrid PET/MRI using a 3D depth camera.

Lynn J Frohwein1, Mirco Heß, Dominik Schlicher, Konstantin Bolwin, Florian Büther, Xiaoyi Jiang, Klaus P Schäfers.   

Abstract

PET attenuation correction for flexible MRI radio frequency surface coils in hybrid PET/MRI is still a challenging task, as position and shape of these coils conform to large inter-patient variabilities. The purpose of this feasibility study is to develop a novel method for the incorporation of attenuation information about flexible surface coils in PET reconstruction using the Microsoft Kinect V2 depth camera. The depth information is used to determine a dense point cloud of the coil's surface representing the shape of the coil. From a CT template-acquired once in advance-surface information of the coil is extracted likewise and converted into a point cloud. The two point clouds are then registered using a combination of an iterative-closest-point (ICP) method and a partially rigid registration step. Using the transformation derived through the point clouds, the CT template is warped and thereby adapted to the PET/MRI scan setup. The transformed CT template is converted into an attenuation map from Hounsfield units into linear attenuation coefficients. The resulting fitted attenuation map is then integrated into the MRI-based patient-specific DIXON-based attenuation map of the actual PET/MRI scan. A reconstruction of phantom PET data acquired with the coil present in the field-of-view (FoV), but without the corresponding coil attenuation map, shows large artifacts in regions close to the coil. The overall count loss is determined to be around 13% compared to a PET scan without the coil present in the FoV. A reconstruction using the new μ-map resulted in strongly reduced artifacts as well as increased overall PET intensities with a remaining relative difference of about 1% to a PET scan without the coil in the FoV.

Entities:  

Mesh:

Year:  2018        PMID: 29186008     DOI: 10.1088/1361-6560/aa9e2f

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

Review 1.  Emerging role of integrated PET-MRI in osteoarthritis.

Authors:  Amarnath Jena; Sangeeta Taneja; Prerana Rana; Nidhi Goyal; Abhishek Vaish; Rajesh Botchu; Raju Vaishya
Journal:  Skeletal Radiol       Date:  2021-06-29       Impact factor: 2.199

Review 2.  Applications of PET-MRI in musculoskeletal disease.

Authors:  Feliks Kogan; Stephen M Broski; Daehyun Yoon; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2018-07       Impact factor: 4.813

3.  Evaluation of a Dedicated Radiofrequency Carotid PET/MRI Coil.

Authors:  Mueez Aizaz; Jochem A J van der Pol; Roel Wierts; Hans Zwart; Abe J van der Werf; Joachim E Wildberger; Jan A Bucerius; Rik P M Moonen; Marianne Eline Kooi
Journal:  J Clin Med       Date:  2022-05-04       Impact factor: 4.241

4.  Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging.

Authors:  Adam Farag; R Terry Thompson; Jonathan D Thiessen; Heather Biernaski; Frank S Prato; Jean Théberge
Journal:  Eur J Hybrid Imaging       Date:  2020-05-12

5.  Assessment of a novel 32-channel phased array for cardiovascular hybrid PET/MRI imaging: MRI performance.

Authors:  Adam Farag; R Terry Thompson; Jonathan D Thiessen; John Butler; Frank S Prato; Jean Théberge
Journal:  Eur J Hybrid Imaging       Date:  2019-08-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.