Metal-on-Metal Hip Replacement: MRI Signal Intensities of Different Body Tissues and Their Relations to Blood Metal Ion Levels.

Einat Slonimsky1,2, Tammar Kushnir1,2, Assaf Kadar3,2, Aharon Menahem3,2, Alon Grundshtein3,2, Steven Velekes4, Merav Lidar5, Shmuel Dekel5, Iris Eshed1,2.   

Abstract

BACKGROUND: Metal-on-metal total hip prostheses (MoM-THR) have been shown to produce hypersensitivity reactions and fluid collection (pseudotumor) by the hip as well as high blood metal ions levels (BMILs).
OBJECTIVES: To evaluate the magnetic resonance imaging (MRI) signal-to-noise ratio (S/N) in selected body tissues around the hip of patients who underwent MoM hip replacement and to correlate to BMILs.
METHODS: Sixty-one MRI hip examinations in 54 post-MoM-THR patients (18 males, 36 females, mean age 65 years) were retrospectively evaluated independently by two readers. The mean S/N ratio in a region of interest was calculated for periprosthetic pseudotumor collection (PPC), the bladder, fat, and muscle on axial T1w, FSE-T2w, and short tau inversion recovery (STIR) sequences on the same location. BMILs were retrieved from patient files.
RESULTS: PPC was detected in 32 patients (52%) with an average volume of 82.48 mm3. BMIL did not correlate with the presence of PPCs but positively correlated with the PPC's volume. A trend for positive correlation was found between BMILs and S/N levels of STIR images for muscle and bladder as well as for PPC and cobalt levels. A trend for correlation was also seen between BMIL with PPC's T1 w S/N.
CONCLUSIONS: Alteration of MRI S/N for different hip tissues showed a tendency for correlation with BMILs, possibly suggesting that metal deposition occurs in the PPC as well as in the surrounding tissues and bladder.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29185279

Source DB:  PubMed          Journal:  Isr Med Assoc J            Impact factor:   0.892