Literature DB >> 29183690

Home-based intravenous analgesia with elastomeric pump as an outpatient procedure for pain control after anterior cruciate ligament repair.

J Villalba1, J Peñalver2, P Torner2, M Serra3, J Planell3.   

Abstract

OBJECTIVE: To follow up pain in the immediate postoperative period, using an elastomeric pump in anterior cruciate ligament surgery.
MATERIAL AND METHODS: 309 patients who had undergone anterior cruciate ligament repair with bone-tendon-bone allograft. Pain control was assessed with a visual analogue scale (VAS) during the immediate postoperative period, in the postoperative care unit, in the recovery room, and after the first 24-48-72hours following home discharge. The need for rescue medication, adverse effects observed and emergency visits were also registered.
RESULTS: 309 patients were assessed (264 males, 45 females), mean age 33 (range: 18 - 55). Postoperative pain was mild in 44.7% of patients, and 38.5% were pain-free. At discharge, 41.1% of patients reported mild pain and 57% were pain-free. At home, mild to moderate levels of pain were maintained and over 97% of patients presented VAS values ≤ 3. Fewer than 3% had adverse effects, 8.7% had to use analgesic medication at some point. Pruritus occurred in less than 1% of patients receiving intravenous analgesia at home, and fewer than 2% had device-related complications. DISCUSSION: There is no consensus regarding the postoperative management of anterior cruciate ligament lesions, although most surgeons use multimode anaesthesia and different combinations of analgesics to reduce postoperative pain.
CONCLUSIONS: The use of an intravenous elastomeric pump as postoperative analgesia for anterior cruciate ligamentoplasty has yielded good results.
Copyright © 2017. Publicado por Elsevier España, S.L.U.

Entities:  

Keywords:  Anterior cruciate ligament; Bomba elastomérica; Elastomeric pump; Ligamento cruzado anterior; Outpatient treatment; Tratamiento ambulatorio

Mesh:

Substances:

Year:  2017        PMID: 29183690     DOI: 10.1016/j.recot.2017.07.005

Source DB:  PubMed          Journal:  Rev Esp Cir Ortop Traumatol (Engl Ed)        ISSN: 2173-576X


  1 in total

1.  Impact of air temperature and drug concentration on liquid emission from elastomeric pumps.

Authors:  Tomoya Abe; Kazumasa Matsuzaka; Toshiaki Nakayama; Masanobu Otsuka; Atsunobu Sagara; Fumiaki Sato; Tetsuro Yumoto