Literature DB >> 29180835

Laminated and infused Parafilm® - paper for paper-based analytical devices.

Yong Shin Kim1, Yuanyuan Yang2, Charles S Henry2,3.   

Abstract

Numerous fabrication methods have been reported for microfluidic paper-based analytical devices (μPADs) using barrier materials ranging from photoresist to wax. While these methods have been used with wide success, consistently producing small, high-resolution features using materials and methods that are compatible with solvents and surfactants remains a challenge. Two new methods are presented here for generating μPADs with well-defined, high-resolution structures compatible with solvents and surfactant-containing solutions by partially or fully fusing paper with Parafilm® followed by cutting with a CO2 laser cutter. Partial fusion leads to laminated paper (l-paper) while the complete fusion results in infused paper (i-paper). Patterned structures in l-paper were fabricated by selective removal of the paper but not the underlying Parafilm® using a benchtop CO2 laser. Under optimized conditions, a gap as small as 137 ± 22 μm could be generated. Using this approach, a miniaturized paper 384-zone plate, consisting of circular detection elements with a diameter of 1.86 mm, was fabricated in 64 × 43 mm2 area. Furthermore, these ablation-patterned substrates were confirmed to be compatible with surfactant solutions and common organic solvents (methanol, acetonitrile and dimethylformamide), which has been achieved by very few μPAD patterning techniques. Patterns in i-paper were created by completely cutting out zones of the i-paper and then fixing pre-cut paper into these openings similar to the strategy of fitting a jigsaw piece into a puzzle. Upon heating, unmodified paper was readily sealed into these openings due to partial reflow of the paraffin into the paper. This unique and simple bonding method was illustrated by two types of 3D μPADs, a push-on valve and a time-gated flow distributor, without adding adhesive layers. The free-standing jigsaw-patterned sheets showed good structural stability and solution compatibility, which provided a facile alternative method for fabricating complicated μPADs.

Entities:  

Keywords:  Microfluidic paper-based analytical device; Paper zone plate; Paper-based flow distributor; Paper-based valve; Parafilm® paper

Year:  2018        PMID: 29180835      PMCID: PMC5701284          DOI: 10.1016/j.snb.2017.10.005

Source DB:  PubMed          Journal:  Sens Actuators B Chem        ISSN: 0925-4005            Impact factor:   7.460


  33 in total

1.  Three-dimensional paper microfluidic devices assembled using the principles of origami.

Authors:  Hong Liu; Richard M Crooks
Journal:  J Am Chem Soc       Date:  2011-10-17       Impact factor: 15.419

2.  High throughput method for prototyping three-dimensional, paper-based microfluidic devices.

Authors:  Gregory G Lewis; Matthew J DiTucci; Matthew S Baker; Scott T Phillips
Journal:  Lab Chip       Date:  2012-06-15       Impact factor: 6.799

3.  Understanding wax printing: a simple micropatterning process for paper-based microfluidics.

Authors:  Emanuel Carrilho; Andres W Martinez; George M Whitesides
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

4.  Flexographically printed fluidic structures in paper.

Authors:  Juuso Olkkonen; Kaisa Lehtinen; Tomi Erho
Journal:  Anal Chem       Date:  2010-11-23       Impact factor: 6.986

5.  A low-cost, simple, and rapid fabrication method for paper-based microfluidics using wax screen-printing.

Authors:  Wijitar Dungchai; Orawon Chailapakul; Charles S Henry
Journal:  Analyst       Date:  2010-09-27       Impact factor: 4.616

6.  Rapid fabrication of pressure-driven open-channel microfluidic devices in omniphobic R(F) paper.

Authors:  Ana C Glavan; Ramses V Martinez; E Jane Maxwell; Anand Bala Subramaniam; Rui M D Nunes; Siowling Soh; George M Whitesides
Journal:  Lab Chip       Date:  2013-08-07       Impact factor: 6.799

7.  Method for fabrication of paper-based microfluidic devices by alkylsilane self-assembling and UV/O3-patterning.

Authors:  Qiaohong He; Cuicui Ma; Xianqiao Hu; Hengwu Chen
Journal:  Anal Chem       Date:  2013-01-07       Impact factor: 6.986

8.  Paper and toner three-dimensional fluidic devices: programming fluid flow to improve point-of-care diagnostics.

Authors:  Kevin M Schilling; Daisy Jauregui; Andres W Martinez
Journal:  Lab Chip       Date:  2013-02-21       Impact factor: 6.799

9.  Controlled reagent transport in disposable 2D paper networks.

Authors:  Elain Fu; Barry Lutz; Peter Kauffman; Paul Yager
Journal:  Lab Chip       Date:  2010-01-15       Impact factor: 6.799

10.  Inkjet-printed microfluidic multianalyte chemical sensing paper.

Authors:  Koji Abe; Koji Suzuki; Daniel Citterio
Journal:  Anal Chem       Date:  2008-08-13       Impact factor: 6.986

View more
  6 in total

1.  Microfluidics for the study of mechanotransduction.

Authors:  Christian M Griffith; Stephanie A Huang; Crescentia Cho; Tanmay M Khare; Matthew Rich; Gi-Hun Lee; Frances S Ligler; Brian O Diekman; William J Polacheck
Journal:  J Phys D Appl Phys       Date:  2020-04-02       Impact factor: 3.207

Review 2.  Current Advancements and Future Road Map to Develop ASSURED Microfluidic Biosensors for Infectious and Non-Infectious Diseases.

Authors:  Tanu Bhardwaj; Lakshmi Narashimhan Ramana; Tarun Kumar Sharma
Journal:  Biosensors (Basel)       Date:  2022-05-20

3.  Ciprofloxacin-loaded dissolving polymeric microneedles as a potential therapeutic for the treatment of S. aureus skin infections.

Authors:  Sharif Abdelghany; Walhan Alshaer; Yazan Al Thaher; Maram Al Fawares; Amal G Al-Bakri; Saja Zuriekat; Randa Sh Mansour
Journal:  Beilstein J Nanotechnol       Date:  2022-06-15       Impact factor: 3.272

Review 4.  Paper-Based Sensors: Emerging Themes and Applications.

Authors:  Amrita Tribhuwan Singh; Darlin Lantigua; Akhil Meka; Shainlee Taing; Manjot Pandher; Gulden Camci-Unal
Journal:  Sensors (Basel)       Date:  2018-08-28       Impact factor: 3.576

5.  A Flexible Method for Nanofiber-based 3D Microfluidic Device Fabrication for Water Quality Monitoring.

Authors:  Xiaojun Chen; Deyun Mo; Manfeng Gong
Journal:  Micromachines (Basel)       Date:  2020-03-06       Impact factor: 2.891

6.  Rapid, Simple and Inexpensive Fabrication of Paper-Based Analytical Devices by Parafilm® Hot Pressing.

Authors:  Surasak Kasetsirikul; Kimberley Clack; Muhammad J A Shiddiky; Nam-Trung Nguyen
Journal:  Micromachines (Basel)       Date:  2021-12-29       Impact factor: 2.891

  6 in total