Literature DB >> 29178126

A comparison between McGrath MAC videolaryngoscopy and Macintosh laryngoscopy in children.

J E Kim1, H J Kwak2, W S Jung2, M Y Chang1, S Y Lee1, J Y Kim1.   

Abstract

BACKGROUND: This prospective, randomised, controlled study was performed to evaluate the usefulness of the McGrath VL compared with Macintosh laryngoscopy in children with expected normal airway during endotracheal intubation, by comparing the time to intubation and difficulty of intubation.
METHODS: Eighty-four patients aged 1-10 years who underwent endotracheal intubation for elective surgery were randomly assigned to the McGrath group (n = 42) or the Macintosh group (n = 42). Anaesthesia was induced with 2.5-3.0 mg/kg of propofol and sevoflurane 5-8 vol%. Orotracheal intubation was performed 2 min after injection of rocuronium 0.6 mg/kg with McGrath VL or Macintosh laryngoscope; the primary outcome was the time to intubation. The Cormack and Lehane glottic grade, intubation difficulty score (IDS), and success rate on intubation were assessed. Haemodynamic changes were also recorded.
RESULTS: As the primary outcome, median time to intubation [interquartile range] did not differ between the McGrath group and the Macintosh group (25.0 [22.8-28.3] s vs. 26.0 [24.0-29.0] s, P = 0.301). The incidence of grade I glottic view was significantly higher in the McGrath group than in the Macintosh group (95% vs. 74%, P = 0.013). Median IDS was lower in the McGrath group than in the Macintosh group (0 [0-0] vs. 0 [0-1], P = 0.018). There were no significant differences in success rate on intubation or haemodynamics between the two groups.
CONCLUSIONS: McGrath VL provides better laryngeal views and lower IDS but similar intubation times and success rates compared with the Macintosh laryngoscope in children with normal airway.
© 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2017        PMID: 29178126     DOI: 10.1111/aas.13043

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  5 in total

1.  Comparison of self-assembled video laryngoscope versus McGrath MAC®: A randomised controlled trial.

Authors:  Besthadi Sukmono; Sidharta K Manggala; Aino N Auerkari; Budiani Christina
Journal:  Indian J Anaesth       Date:  2022-05-19

2.  Comparison between video-lighted stylet (Intular Scope™) and direct laryngoscope for endotracheal intubation in patients with normal airway.

Authors:  Ji Yeon Lee; Ho Jin Hur; Hee Yeon Park; Wol Seon Jung; Jiro Kim; Hyun Jeong Kwak
Journal:  J Int Med Res       Date:  2020-11       Impact factor: 1.671

Review 3.  Video screen visualization patterns when using a video laryngoscope for tracheal intubation: A systematic review.

Authors:  Preston Dean; Benjamin Kerrey
Journal:  J Am Coll Emerg Physicians Open       Date:  2022-01-06

4.  The relationship between years of anesthesia experience and first-time intubation success rate with direct laryngoscope and video laryngoscope in infants: a retrospective observational study.

Authors:  Yuka Uchinami; Noriaki Fujita; Takashi Ando; Kazuyuki Mizunoya; Koji Hoshino; Isao Yokota; Yuji Morimoto
Journal:  J Anesth       Date:  2022-09-20       Impact factor: 2.931

5.  Comparison of McGrath Videolaryngoscope and Macintosh Laryngoscope in Children with Torticollis: Randomized Controlled Trial.

Authors:  Min Hur; Jong Yeop Kim; Sang Kee Min; Kyuheok Lee; Young Ju Won; Ji Eun Kim
Journal:  Children (Basel)       Date:  2021-12-10