Literature DB >> 29174779

External Suction and Fluid Output in Chest Drains After Lobectomy: A Randomized Clinical Trial.

Marike Lijkendijk1, Kirsten Neckelmann2, Peter B Licht2.   

Abstract

BACKGROUND: Even when air leakage has ceased completely after lobectomy, chest drains are often not removed because of high fluid output. Accepted thresholds for removal vary between institutions but typically range between 200 and 500 mL/d. There is little knowledge whether external suction influences the amount of fluid.
METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours.
RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 mL) and 48 hours (616 ± 366 mL versus 1067 ± 387 mL (p < 0.001). Repeated measure analysis (mixed model) demonstrated that in addition to suction level the surgical approach (video-assisted thoracoscopic surgery/thoracotomy, p = 0.04) and affected lobe (upper/lower, p = 0.001) were significant predictors of fluid production.
CONCLUSIONS: Increased suction levels lead to increased fluid output. Thoracotomy and lower lobectomy are associated with increased fluid output in chest drains, which should be taken into consideration if algorithms for chest drain removal include an upper limit of fluid output.
Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 29174779     DOI: 10.1016/j.athoracsur.2017.08.048

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Less is more: the benefits of low suction for digital pleural drainage devices after pulmonary resection.

Authors:  Stephen Donald Gowing; Virginia Ferreira Resende; Sebastien Gilbert
Journal:  J Thorac Dis       Date:  2019-09       Impact factor: 2.895

Review 2.  Summary of best evidence for enhanced recovery after surgery for patients undergoing lung cancer operations.

Authors:  Yutong Lu; Zhenwei Yuan; Yuqiang Han; Yanfang Zhang; Renhua Xu
Journal:  Asia Pac J Oncol Nurs       Date:  2022-03-26

3.  Electronic chest tube drainage devices and low suction following video-assisted thoracoscopic pulmonary lobectomy.

Authors:  Jessica A Bowman; Garth H Utter
Journal:  J Thorac Dis       Date:  2019-05       Impact factor: 3.005

4.  What is the optimal level of suction on digital chest drainage devices following pulmonary lobectomy?

Authors:  Marlene Fromm Sørensen; Bo Laksáfoss Holbek; René Horsleben Petersen; Thomas Decker Christensen
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-27

5.  Single versus double chest drains after pulmonary lobectomy: a systematic review and meta-analysis.

Authors:  Jinzhi You; Hailing Zhang; Wei Li; Ninghuang Dai; Zhongfeng Zheng
Journal:  World J Surg Oncol       Date:  2020-07-20       Impact factor: 2.754

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.