Literature DB >> 29171939

Initial flow cytometric evaluation of the Clearllab lymphoid screen.

B D Hedley1, G Cheng2, J Luider3, W Kern4, G Lozanski5, I Chin-Yee6, L E Lowes1, M Keeney1, D Careaga2, R Magari2, L Tejidor2.   

Abstract

INTRODUCTION: Flow cytometric immunophenotyping (FCI) is an integral part in the diagnosis and classification of hematologic malignancies. FCI results also influence therapeutic decisions and disease prognosis. ClearLLab LS is a 12-antibody 10-color cocktail provided in dry format designed as a screen for patients suspected of having hematolymphoid disease.
METHODS: A blinded comparison between ClearLLab LS, (CD8-FITC, Kappa-FITC,CD4-PE, Lambda-PE, CD19-ECD, CD56-PE-Cy5.5, CD10-PE-Cy7, CD34-APC, CD5-APC-A700, CD20-APC-A750, CD3-PB, and CD45-KrO), ClearLLab Reagents (five-color, 17-antibodies) and individual Laboratory Developed Tests (LDTs), was conducted at four laboratories. Evaluation of ClearLLab LS was performed on 210 specimens, compared to the five-color ClearLLab Reagents (IVD and CE-IVD), and a subset (n = 167) to LDTs.
RESULTS: ClearLLab LS showed good agreement to ClearLLab Reagents in detecting the absence (104/104) or presence (106/106) of abnormal populations. Of specimens with abnormal populations the ClearLLab LS agreed with the ClearLLab Reagent for neoplasm maturity assessment (70/70 mature and 36/36 immature). Out of 167 specimens with LDTs results, 86 contained abnormal population(s), ClearLLab LS detected 82 (95.3%) of cases. Of the 4 cases not detected by ClearLLab LS, 3 were plasma cell neoplasms and 1 was a mature T cell malignancy. Eighty-one samples with no hematological malignancy as analyzed by LDT were also negative by ClearLLab LS (100% agreement). ClearLLab LS agreed with LDTs assessment of neoplasms' maturity (55/55 mature and 27/27 immature).
CONCLUSION: ClearLLab LS screening tube showed excellent agreement between ClearLLab Reagents and with LDT's. The presence of CD34 and CD10 in the tube allowed the detection of blast populations in several acute leukemias and myeloid neoplasms that were tested.
© 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

Entities:  

Keywords:  flow cytometry; immunophenotyping; leukemia; lymphoma

Mesh:

Year:  2017        PMID: 29171939     DOI: 10.1002/cyto.b.21603

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.058


  3 in total

1.  A multicenter study evaluation of the ClearLLab 10C panels.

Authors:  Benjamin D Hedley; Guoyan Cheng; Michael Keeney; Wolfgang Kern; Adrian Padurean; Joanne Luider; Ian Chin-Yee; Lori E Lowes; Justin Rohrbach; Robert Ortega; Astrid Smit; Ka-Wai Lo; Robert Magari; Liliana Tejidor
Journal:  Cytometry B Clin Cytom       Date:  2020-07-15       Impact factor: 3.058

2.  Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa.

Authors:  Deborah K Glencross; Leanne Swart; Melanie Pretorius; Denise Lawrie
Journal:  Afr J Lab Med       Date:  2022-07-15

3.  Flow cytometry lyophilised-reagent tube for quantifying peripheral blood neutrophil myeloperoxidase expression in myelodysplastic syndromes (MPO-MDS-Develop): protocol for a diagnostic accuracy study.

Authors:  Tatiana Raskovalova; Laura Scheffen; Marie-Christine Jacob; Simon Chevalier; Sylvie Tondeur; Bénédicte Bulabois; Mathieu Meunier; Gautier Szymanski; Christine Lefebvre; Charlotte Planta; Chantal Dumestre-Perard; Nicolas Gonnet; Frédéric Garban; Raymond Merle; Sophie Park; José Labarère
Journal:  BMJ Open       Date:  2022-10-07       Impact factor: 3.006

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.